Technical documentation
Technical documentation
STESP ed 02/02
25
EOLO SUPERIOR PLUS
EOLO Superior PLUS OPERATION SEQUENCE
Central-heating phase
D.h.w. phase
STARTING
STARTING
Main switch in WINTER position
Main switch in SUMMER or WINTER position
⇓⇓
⇓⇓
MODULATION CARD AND
CAR (
remote
control
)
POWER SUPPLY
MODULATION CARD AND CAR
(
remote
control
)
POWER SUPPLY
When the main switch contacts close
(WINTER position)
the modulation board and CAR (
if fitted
) are powered and
operation in central-heating mode is enabled
When the main switch contacts close
(SUMMER position)
the modulation board and CAR (
if fitted
) are powered and
operation in d.h.w. is enabled
⇓⇓
⇓⇓
CLOSING OF ROOM THERM. SWITCH
/ CAR
OPER. REQUEST
DOMESTIC HOT WATER OPERATION
REQUEST
Room thermo. or CAR (
if fitted
) request detects conditions
that require operation in central-heating phase
External storage tank water temperature below that set
⇓⇓
⇓⇓
PUMP AND 3-WAY VALVE POWER SUPPLY
PUMP AND 3-WAY VALVE POWER SUPPLY
The modulation board powers the circulator and the electric
3-way valve
The valve is moved to central-heating position
The modulation board powers the circulator and the electric
3.-way valve.
The valve is moved to d.h.w. position
⇓⇓
⇓⇓
CLOSING OF PUMP PRESSURE MICROSWITCH
The circulation of water inside the primary circuit causes the closing of the pump pressure
switch
⇓⇓
FLUE PRESSURE SWITCH CONTACT CONTROL
The card checks the correct position of the flue pressure switch
(contact NC (normally closed)
⇓⇓
FAN POWER SUPPLY
The modulation board powers the fan
⇓⇓
FLUE PRESSURE SWITCH CONTACT CONTROL
The modulation board checks the deviation of the flue pressure switch contact following fan
operation
(contact normally open (NO)
⇓⇓
IGNITION CONTROL UNIT POWER SUPPLY
The modulation board controls the ignition control unit
⇓⇓
IGNITION ELECTRODES POWER SUPPLY
The control unit powers the ignition electrodes
⇓⇓
GAS VALVE POWER SUPPLY
With the consensus of the overheating thermostat, the control unit powers the gas valve coils.
⇓⇓
BURNER IGNITION
(SOFT)
For a few seconds, the board conveys soft-ignition power to the modulation coil
⇓⇓
FLAME DETECTION
By means of the ionisation electrode, the ignition cardt detects burner ignition and conveys
the burner ignition signal to the modulation board
⇓⇓
BOILER OPERATION
The burner operates at an output that varies according to the type of request, the
adjustments/settings made and the temperatures read by the NTC sensors