background image

G

Never pull the mains cable to disconnect the
mains plug from the mains socket, always seize
the plug.

G

For cleaning the housing only use a dry, soft
cloth, never use water or chemicals.

G

No guarantee claims for the unit and no liability
for any resulting personal damage or material
damage will be accepted if the unit is used for
other purposes than originally intended, if it is not
correctly installed or connected or operated, or
not repaired in an expert way.

G

Important for U. K. Customers!

The wires in this mains lead are coloured in
accord ance with the following code:

green/yellow = earth

blue = neutral

brown = live

As the colours of the wires in the mains lead of
this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:

1. The wire which is coloured green and yellow

must be connected to the terminal in the plug
which is marked with the letter E or by the earth
symbol  , or coloured green or green and yel-
low.

2. The wire which is coloured blue must be con-

nected to the terminal which is marked with the
letter N or coloured black.

3. The wire which is coloured brown must be con-

nected to the terminal which is marked with the
letter L or coloured red.

Warning – This appliance must be earthed.

3

Applications

The laser effect unit projects a variety of red and
green patterns of light spots onto a surface or into
an artificial fog. It can be used e. g. on stage or in
discotheques.

The laser unit is designed for control via a DMX

light controller (8 DMX control channels). However,
it can also be operated on its own, by music control
via the integrated microphone or by creating differ-
ent patterns of light spots via two light show pro-
grammes.

4

Mounting and Setting into Operation

The laser must safely be mounted in an expert way.
The person who sets up the unit together with all
additional components (e. g. mirror, lenses, projec-
tion surface) to create a laser system, becomes the
legitimate manufacturer of this system. 

Observe in

any case the warning notes in chapter 2.1.

1) Tightly screw the laser with the mounting

bracket (3) to a suitable place, e. g. with a stable
mounting screw or a support for lighting units 
(C hook) at a cross bar.

2) To align the unit, release the two setscrews (1)

at the mounting bracket. Adjust the desired incli-
nation of the unit and retighten the screws.

3) Connect the supplied mains cable to the mains

jack (12) first and then to a socket (230 V~ 

/

50 Hz).

4) Switch on the laser with the switch (10) on the

rear side. The red LED POWER (4) lights up as
a power indication.

5) To switch on the laser beams, insert the supplied

key in the lock of the switch LOCK (6) and turn
the key to the right.

IMPORTANT!

The laser system must 

not

be

operated 

without

the presence of

a laser pro-

tection adviser.

In case of absence, this advi-

sor should have secured the laser with the key
switch against unauthorized operation.

WARNING

1. According to international safety

regulations the laser must be
installed so that the laser beam
has a minimum distance of 3 m to
the floor when persons stand or sit

under the beam (fig. 2). However, the unit can also
be installed so that in the horizontal plane the
laser beam keeps a minimum distance of 2.5 m to
persons (fig. 3).

2. As the safety regulations are different in each

country, the regulations of the country where
the unit will be operated must be observed in
any case.

3. Select the mounting location so that a sufficient

air circulation will be ensured during operation.
The unit must have a minimum distance of
50 cm to adjoining surfaces and the air vents at
the housing must not be covered in any case.

4. If the laser is installed at a place where people

may stand or sit under, it must additionally be
secured, e. g. by a safety rope. Lead the safety
rope through the safety lug (8) and fix it so that
the maximum falling distance of the unit does
not exceed 20 cm.

If the unit is to be put out of operation
definitively, take it to a local recycling plant
for a disposal which is not harmful to the
environment.

9

GB

Содержание LSE-150RG

Страница 1: ...TRUZIONI PER L USO GEBRUIKSAANWIJZING MANUAL DE INSTRUCCIONES INSTRUKCJA OBS UGI SIKKERHEDSOPLYSNINGER S KERHETSF RESKRIFTER TURVALLISUUDESTA DMX LASER EFFEKTGER T DMX LASER EFFECT UNIT LASER DMX UNIT...

Страница 2: ...ge Line Por favor lea estas instrucciones de uso atentamente antes de hacer funcionar el aparato De esta manera conocer todas las funciones de la unidad se prevendr n errores de operaci n usted y el a...

Страница 3: ...10 11 12 13 14 15 16 17 Sicherheitsabst nde Safety distances Distances de s curit Distanze di sicurezza Veiligheidsafstanden Distancias de seguridad Bezpieczny dystans 6 7 8 9 1 2 3 4 1 5 FUNC FUNC U...

Страница 4: ...DMX Pin 3 DMX 2 Hinweise f r den sicheren Gebrauch Das Ger t entspricht allen relevanten Richtlinien der EU und ist deshalb mit gekennzeichnet 2 1 Hinweise speziell f r Laserger te Das Ger t entspric...

Страница 5: ...des Ger tes einstellen und die Schrauben wieder fest anziehen 3 Das beiliegende Netzkabel zuerst in die Netz buchse 12 stecken und dann in eine Steck dose 230 V 50 Hz 4 Das Ger t mit dem Schalter 10...

Страница 6: ...Display nicht mehr 6 Bedienung ber ein Lichtsteuerger t Zur Bedienung ber ein Lichtsteuerger t mit DMX512 Protokoll z B DMX 1440 oder DMX 510USB von img Stage Line verf gt das Laser ger t ber 8 DMX S...

Страница 7: ...serdioden kein Garantieanspruch 8 1 Funktionen der DMX Kan le Wenn durch den DMX Kanal 8 die Stroboskop Funktion ausgeschaltet ist leuchten bei diesen DMX Werten die roten und gr nen Strahlen kontinui...

Страница 8: ...marked with 2 1 Notes especially for laser units This laser corresponds to the class 3b The lasers have the following power and wavelengths 2 2 General safety notes It is essential to observe the fol...

Страница 9: ...to create a laser system becomes the legitimate manufacturer of this system Observe in any case the warning notes in chapter 2 1 1 Tightly screw the laser with the mounting bracket 3 to a suitable pla...

Страница 10: ...the slave mode Press the button FUNC 15 so many times until flashes on the display 9 Memorize the mode with the button ENTER As soon as control sig nals of the master unit are received the display st...

Страница 11: ...er diodes will be accepted 8 1 Functions of the DMX channels If the stroboscope function is switched off by the DMX channel 8 the red and green beams light up continuously with these DMX values Subjec...

Страница 12: ...es n ces saires de l Union europ enne et porte donc le sym bole 2 1 Conseils sp cifiques pour les lasers L appareil r ponde la classe 3b Les lasers ont les puissances et longueurs d onde suivantes 2 2...

Страница 13: ...tage R glez l inclinaison voulue de l appareil et revissez 3 Reliez le cordon secteur livr la prise 12 et reliez l autre extr mit du cordon une prise secteur 230 V 50 Hz 4 Allumez l appareil avec l in...

Страница 14: ...ouche ENTER D s que les signaux de commande de l appareil principal sont re us l affichage ne clignote plus 6 Utilisation via un contr leur Pour une utilisation via un contr leur avec proto cole DMX51...

Страница 15: ...nction stroboscope est d sactiv e par le canal DMX 8 les faisceaux verts et rouges brillent en continu pour ces valeurs DMX Tout droit de modification r serv Valeur DMX Fonction Canal 1 mode de foncti...

Страница 16: ...rtenze di sicurezza L apparecchio conforme a tutte le direttive richie ste dell UE e pertanto porta la sigla 2 1 Avvertenze speciali per apparecchi laser L apparecchio corrisponde alla classe 3b per i...

Страница 17: ...e due viti di bloccaggio 1 sulla staffa di montaggio Impo stare l inclinazione desiderata e stringere nuo vamente le viti 3 Inserire il cavo in dotazione nella sua presa 12 e quindi in una presa di re...

Страница 18: ...ay 9 si vede lampeggiare Memorizzare il modo con il tasto ENTER Quando si ricevono i segnali di comando dall apparecchio principale il display smette di lampeggiare 6 Comando attraverso un unit di com...

Страница 19: ...i dei canali DMX Se tramite il canale DMX 8 la funzione stroboscopio disattivata con questi valori DMX i raggi rossi e verdi sono accesi continuamente Con riserva di modifiche tecniche Valore DMX Funz...

Страница 20: ...laar pen 1 massa pen 2 DMX pen 3 DMX 2 Veiligheidsvoorschriften Het apparaat is in overeenstemming met alle relevante EU Richtlijnen en is daarom gekenmerkt met 2 1 Specifieke aanwijzingen voor lasera...

Страница 21: ...rvolgens in een stopcontact 230 V 50 Hz 4 Schakel het apparaat in met de schakelaar 10 op de achterzijde De rode POWER LED 4 licht op bij bedrijf 5 Om de laserstralen in te schakelen steekt u de bijge...

Страница 22: ...display met knipperen 6 Bediening via een lichtregelaar Voor de bediening via een lichtregelaar met DMX512 protocol b v DMX 1440 of DMX 510USB van img Stage Line beschikt het laser apparaat over 8 DMX...

Страница 23: ...ties van de DMX kanalen Als door het DMX kanaal 8 de stroboscoopfunctie uitge schakeld is lichten bij deze DMX waarden de rode en groene stralen permanent op Wijzigingen voorbehouden DMX waarde Functi...

Страница 24: ...1 masa pin 2 DMX pin 3 DMX 2 Notas de Seguridad El aparato cumple con todas las directivas requeri das por la UE y por lo tanto est marcado con el s mbolo 2 1 Notas especiales para aparatos l ser El...

Страница 25: ...riente 12 primero y luego a un enchufe 230 V 50 Hz 4 Conecte el l ser con el interruptor 10 de la parte posterior El LED rojo POWER 4 se ilu mina como indicaci n 5 Para encender los haces del l ser in...

Страница 26: ...to se reciben se ales de control del aparato Master el visua lizador deja de parpadear 6 Funcionamiento mediante un Controlador Para funcionar mediante un controlador con proto colo DMX512 p ej DMX 14...

Страница 27: ...se desconecta con el canal DMX 8 los haces rojo y verde se iluminan continuamente con estos valores DMX Sujeto a modificaciones t cnicas Valor DMX Funci n Canal 1 Modo de funcionamiento 000 009 L ser...

Страница 28: ...iat a pin 1 masa pin 2 DMX pin 3 DMX 2 rodki bezpiecze stwa Urz dzenie spe nia wszystkie wymagania norm UE dzi ki czemu zosta o oznaczone symbolem 2 1 Uwagi dotycz ce laser w Niniejsze urz dzenie nale...

Страница 29: ...do ciany lub do poprzeczki sta tywu o wietleniowego za pomoc zaczep w kszta t C 2 Dla uzyskania danej pozycji poluzowa regu latory uchwytu monta owego 1 Ustawi wy bran pozycj i dokr ci je 3 Pod czy do...

Страница 30: ...przestanie miga wy wietlacz 6 Sterowanie poprzez kontroler Urz dzenie mo e by sterowane poprzez kontroler z protoko em DMX512 np DMX 1440 lub DMX 510USB marki img Stage Line Laser wyposa ony jest w 8...

Страница 31: ...niem mo liwo ci zmian Warto DMX Funkcja Kana 1 Tryb pracy 000 009 laser wy czony 010 060 program show z losow sekwencj wzor w 061 110 program show z wolnym przebiegiem 111 160 program show sterowany m...

Страница 32: ...m selve str mstikket G Ved reng ring skal der benyttes en ren t r klud Brug aldrig nogen former for v sker eller kemi kalier G Der ydes ingen garanti og al ansvar fraskrives for personer eller ting s...

Страница 33: ...denne en begr nset levetid Som alle andre sliddele er laser dioden ikke omfattet af garantien ADVARSEL 1 If lge internationale sikkerheds re gulativer skal laserenheden mon teres med en minimums afst...

Страница 34: ...id en mjuk och torr trasa f r reng ring Aldrig vatten eller kemikalier G Inga garantier eller skadest ndsanspr k kan komma vid fr ga vid annan anv ndning av maskinen n det den r avsedd f r om den inte...

Страница 35: ...1 I enlighet med internationella s kerhetsf reskrifter m ste lasern installeras s att l gsta h jd mot sittande eller st ende r tre meter bild 2 Den kan ven monteras horisontellt s att l gsta h jd f r...

Страница 36: ...eh me kangasta l k yt kemikaaleja tai vett G Laitteen takuu raukeaa eik valmistaja maa hantuoja tai myyj ota vastuuta mahdollisista v litt mist tai v lillisist vahingoista jos laitetta on k ytetty muu...

Страница 37: ...alainen osa kuten eiv t muutkaan kulutusosat T RKE Laser j rjestelm ei saa k ytt jos vastuuhenkil ei ole paikalla Vastuuhen kil n tulee lukita laite avainkytkimell silloin kun ei ole paikalla jotta as...

Страница 38: ...MONACOR INTERNATIONAL GmbH Co KG Zum Falsch 36 28307 Bremen Germany Copyright by MONACOR INTERNATIONAL All rights reserved A 1160 99 02 06 2011...

Отзывы: