14
The Electric Terminal identified in the figure below is an additional rotection
for the grounding that is provided in the mains. It must be connected to a
grounding terminal bar, regardless of the connection to the mains, and ther
products that have accessible metallic parts. And which are stationary, must also be
connected to this bus as well as the service bench itself, in case it is of metallic material . In
this way all these products will be under the same electrical power avoiding undesirable
leaking currents.
For your safety, the equipment must be connected to an exclusive 15 A thermoelectric circuit
breaker within a maximum distance of 1.5 m of the oven.
Below is the breaker table for each oven model:
Model
Circuit Breaker (A)
FTE150
– 220 V MF
50
FTE150
– 220 V TF
25
FTE150
– 380 V TF
16
FTE300
– 220 V TF
50
FTE300
– 380 V TF
32
The ovens described in this manual are single voltage, ie 127 V, 110 V or 220 V. If you need to
change the voltage in your equipment, contact the manufacturer or your authorized dealer.
ATTENTION!
Before turning on your equipment, always check that the mains supply voltage is the same as
the equipment voltage. If it is not the same, contact the manufacturer or authorized dealer.
The supply voltage of this equipment is 220 V (50 or 60 Hz) single-phase or 220 V and 380 V
three-phase (50 or 60 Hz), as can be verified on the voltage label affixed to the power cable or
as indicated on the nameplate data label, which is located on the right side of the equipment
(see the figure on this label in item 2.2 of this manual).
Make sure that the voltage of the electrical network where the equipment will be installed is
compatible with the voltage indicated on these labels.
For more details on the rest of the electrical part of the equipment, refer to the electrical diagram
in the annexes of the manual.
Содержание BIMG METVISA FTE.150
Страница 1: ...1 ...
Страница 9: ...9 Follow the guidelines below to assemble the stand ...
Страница 26: ...27 Electrical Schematic FTE 300 Voltage 220 V Three Phase Connection ...
Страница 28: ...29 Electrical Schematic FTE 300 Voltage 380 V Three Phase Connection ...
Страница 29: ...30 Explosion Design ...
Страница 30: ...31 Explosion Design ...
Страница 31: ...32 Explosion Design ...
Страница 32: ...33 Explosion Design ...
Страница 38: ...39 Notes ...
Страница 39: ......