![iMettos GF120 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/imettos/gf120/gf120_instruction-manual_2046701009.webp)
8
1. Open the door.
2. Turn the thermostat OFF (see figure below, view A). The thermostat is located behind the
door.
3. Push the gas control valve knob and turn to OFF. Wait 5 minutes for unburned gas to
vent.
4.
Push and turn gas control valve knob to the “L” in PILOT (see figure below, view B).
5. While still holding the knob in, light the pilot with a lit flame. Continue to depress the knob
until pilot remains lit when knob is released. If the pilot does not remain lit, repeat step 3
through 5.
6. Depress and turn gas control knob to ON (See figure below, view C).
7. If gas supply is interrupted, repeat steps 2 through 6.
TURNING ON THE FRYER
1. Set the temperature knob to desired temperature.
2. After the set temperature has been reached, the thermostat shuts off the gas flow
to burners.
3. The pilot remains lit. The burners will cycle on and off, maintaining the set
temperature.
TURNING OFF THE FRYER
1. Turn the thermostat OFF.
2.
To keep the pilot lit, turn the gas valve to “L” in Pilot.
3. To shut off all gas to the system, including the pilot, turn the gas valve knob to OFF.
EXTENDED SHUTDOWN
1. Turn the thermostat knob to OFF.
2. Push in the pilot knob and turn to OFF.