Enter a VLAN ID in the Management VLAN IDs field.
VLAN IDs Priorities Tags
Current Saved Current Saved
Ports Data VLANs are used only
Optics [0 ] [
13
] [0 ] [
0
] [
N
] if Tags are enabled on both
he Optics and Data Ports.
Data [0 ] [
0
] [0 ] [
0
] [
Y
] t
Management VLAN.........................EXT Mgmt Tag
NMP....[0 ] [20 ] [0 ] [0 ] [ Y ]
S
4.
Press S or F3 to save the settings.
5.
Type reboot.
Now the iMcV-FiberLinX-II is configured to pass only VLAN ID 13 from the DATA
port to the OPTICS (or UPLINK) port. Untagged packets arriving at the OPTICS (or
UPLINK) port (Tags = N) receive a tag (VLAN ID = 13) before being sent out of the
DATA port. The VLAN ID number used for a port must be different than the number
used for the Management VLAN ID tag (VLAN ID=20). The EXT MGMT must have
VLAN=20.
If Y is entered in the EXT MGMT Tag field, the VLAN ID for this port is the value in
the Management VLAN field. In this case, define a VLAN ID in the Management
VLAN field. If the unit is managed through the EXT MGMT port using untagged
frames, the Management VLAN does not need to be defined.
EXT MGMT
VLAN ID=20
OPTICS:
Untagged
DATA:
Data
VLAN ID=13
EXT MGMT Port Management DIP switch 1 set