IV - Installation Instructions
Each iMcV-FiberLinX-II module requires one slot in an iMediaChassis or
MediaChassis. To install the module in a chassis, remove the blank faceplates
covering the slots where you want to install the module. Then slide the module into
the chassis card guides until the module is seated securely in the connector. Secure
the module to the chassis by tightening the captive screw.
The iMcV-FiberLinx-II module includes on-board SNMP logic. A chassis other than
an iMediaChassis series cannot manage an iMcV-FiberLinX-II, so the iMcV-FiberLinX-
II must be managed independently.
When installed in an iMediaChassis, you can manage the iMcV-FiberLinX-II module
from the chassis by using the Unified Management Agent (UMA). Refer to
http://www.imcnetworks.com/Products/Unified_Management_Agent.cfm
for more
information on using UMA with iConfig, iMediaChassis and iMcV-FiberLinX-II. iMcV-
FiberLinX-II modules not managed by UMA must have an IP address assigned to
them after installation before they can be managed. Refer to (I) - Assigning IP
Information for more information.
Small Form-Factor Pluggable Ports (SFP)
iMcV-FiberLinX-II modules are available with an optional SFP port. Since the SFP
port speed is fixed at 100Mbps, you must use a 100 Mbps speed SFP. In addition,
many SFPs, including those from IMC Networks, feature enhanced diagnostics
capabilities with a Digital Diagnostics Monitoring Interface (DDMI). DDMI statistics
provide real-time access to transceiver operating parameters such as voltage,
temperature, laser bias current, and both transmitted and received optical power.
DDMI information can be accessed in iView
2
by clicking Tables > SFP Info.
NOTE
iMcV-FiberLinX-II has been tested with the IMC Networks SFP modules. You can install any MSA-
compliant SFP module. However, IMC Networks does not guarantee the functionality of non-IMC
Networks SFP modules due to possible non-conformity with MSA design standards.
AutoCross Feature for Twisted Pair Connection
All twisted pair ports on the iMcV-FiberLinX-II include AutoCross, a feature that
automatically selects between a crossover workstation and a straight-through
connection depending on the connected device.
V - Software Configuration
The following sections describe the features you can configure. Refer to the iView²
online help for iMcV-FiberLinX-II module configuration information.