LLM-1770
Installation and Operation Manual
41
EBU R 128 Setup
1
Programme
Relative Gating Active
Relative Gating Value
-10 Rel (Fixed)
Short Term Integration
3 Seconds (Fixed)
Max Hold Time
1 Second to 60 Seconds
Infinite*
Range
Relative Gating Active
Relative Gating Value
-20 Rel (Fixed)
Target Loudness
Level
-23 LUFS (Fixed)
High Level Above
0 LU to 10 LU (1 LU*)
Low Level Below
0 LU to 10 LU (1 LU*)
Absolute Gating
-70 LKFS (Fixed)
Arib TR-B32 Displays
1
Program
Short Term
Max True Peak
Range
Arib TR-B32 Setup
1
Program
Relative Gating Active
Relative Gating Value
-10 (Fixed)
Short term Integration
3 seconds (Fixed)
Max hold time
1 Second to 60 Seconds
Infinite*
Range
Relative Gating Active
Relative Gating Value
-20 (Fixed)
Target Loudness
Level
-24LKFS (Fixed)
High level Above
0 LU to 10 LU (1 LU*)
Low level below
0 LU to 10 LU (1 LU*)
Absolute gating
-70 (Fixed)
Custom Displays
1
Program
Short Term
Max True Peak
Range
Table 4-5
Loudness Display Setup Menu
(Continued)
Selection Option
Selection Option
Selection Option
Selection Option
Содержание Videotek LLM-1770
Страница 13: ...LLM 1770 Installation and Operation Manual 7 Figure P 3 WEEE Compliance Symbol...
Страница 14: ...About This Manual 8...
Страница 62: ...Chapter 4 Setup Menu Functions 56...
Страница 68: ...Chapter 5 Alarm Descriptions 62...
Страница 76: ...Chapter 6 External Control 70...
Страница 84: ...Chapter 8 Specifications 78...
Страница 102: ...Appendix C Glossary 96...
Страница 122: ...Index 116...