10
OBS
+
OP
+
5050D and OPSS
+
OP
+
D Installation and Operation Manual
Chapter 2: Installation
Setting the Fiber Input Switch
The OBS
+
OP
+
5050D and OPSS
+
OP
+
D modules have no jumpers to
set.
On the OPSS
+
OP
+
D, a single 3-position switch at the card edge (see
Figure 2-1
) locally controls the fiber inputs, or sets the module to
remote control by CCS. The switch provides the following options:
•
Port 1 Connected
•
Automatic Mode (CCS remote control)
•
Port 2 Connected
Figure 2-1.
Fiber Input Switch
When you select
Port 1 Connected
or
Port 2 Connected
using the
switch, the module accepts the signal as it is received from the
designated port.
When you select
Automatic Mode
control, CCS control panels and
software are enabled. This makes it possible for you to either use
automatic selection (in which the module selects one of the two inputs,
based on light intensity), or manual selection.
When in automatic mode, the module selects the incoming source based
on the
Signal Good Threshold
and the
Switch Threshold
parameter
settings (see
“Setting Parameters” on page 22
).
Local input switch
• Port 1 Connected
• Automatic Mode
• Port 2 Connected