Chapter 2: Installation
Maximum FR6802
+
Frame Power Ratings
OBS
+
OP
+
5050D and OPSS
+
OP
+
D modules operate only in fan-
cooled FR6802
+
frames, subject to the limitations shown in
Table 2-1
.
These modules cannot be installed in 6800/7000 series frames.
CAUTION
To maintain proper temperatures, ensure that the front panel is
closed at all times, and that the fan module is fully operational.
• 0 W (OBS
+
OP
+
5050D)
• <2 W (OPSS
+
OP
+
D)
Table 2-1.
Frame Power Ratings
6800
+
Frame
Type
Power
Supply
Max. Frame
Power
Dissipation
Number of
Usable
Slots
*
Max. Power
Dissipation
Per Slot
OBS
+
OP
+
50-50D and
OPSS
+
OP
+
D
Requirements
FR6802
+
XF
AC
120 W
20
6 W
FR6802
+
XF48
DC
105 W
20
5.25 W
FR6802
+
QXF
AC or
DC
120 W
20
6 W
* Each front module requires two of these slots. Therefore, to calculate the maximum power dissipation
available per module, double the rating shown in the Max. Power Dissipation Per Slot column.