DQS6800
+
Installation and Operation Manual
51
Chapter 3: Operation
CC EIA/
CEA-608-B
Missing
(525 only)
Reports that the standard
definition CC data on line 21
“field 1” is not detected for a
period in excess of the duration
setting
Input
1 240.0
2.0
WSS Missing
(625 only)
Reports that the presence of
Widescreen Signaling for
Widescreen Format is not
detected for a period in excess
of the duration setting.
Input
1 240.0
2.0
Luma Peak
Reports that the luma
component has exceeded the
threshold defined by the
parameter
Input
1 240.0
2.0
Luma Low
Reports that the luma
component remains below the
threshold defined by the
parameter
Input
1 240.0
2.0
Chroma Peak
Reports that the chroma
component has exceeded the
threshold defined by
parameter
Input
1 240.0
2.0
Chroma Low
Reports that the chroma
component remains below the
threshold defined by the
parameter
Input
1 240.0
2.0
Video Black
Reports the input video is black
Input
6
240.0
2.0
CC/XDS Missing
(525 only)
Reports the loss of CCXDS
Input
1
240.0
2.0
Table 3-12. DQS6800
+
SQM Alarms (these alarms appear per input channel) (Continued)
Alarm Name
Alarm Description
Alarm Option Default Settings
Group
Alarm
priority
(range:
1 - 10)
Trigger
(Range:
1 - 7200 sec)
Clear
(Range:
1 - 7200 sec)
Содержание DQS6800+
Страница 3: ...Edition A June 2008 DQS6800 Quad Video Decoder and Synchronizer Installation and Operation Manual...
Страница 4: ......
Страница 8: ...vi DQS6800 Installation and Operation Manual Contents...
Страница 22: ...8 DQS6800 Installation and Operation Manual Chapter 1 Introduction...
Страница 66: ...52 DQS6800 Installation and Operation Manual Chapter 3 Operation...
Страница 78: ...66 DQS6800 Installation and Operation Manual Appendix A Communication and Control Troubleshooting Tips...
Страница 83: ......