26
DAC6800
+
BCA4 and DAC6800
+
BCA4Z Installation and Operation Manual
Chapter 3: Operation
Changing Parameter Settings
Follow these steps to change the DAC6800
+
BCA4 and
DAC6800
+
BCA4Z parameter settings:
1. Rotate the hex switch (mode select rotary switch) to “0.”
2. Once the hex switch is set to “0,” toggle the navigation switch up or
down to select a bank.
View the two control LEDs next to the navigation toggle switch to
see which bank is currently selected. (See
3. Rotate the hex switch to the parameter number (1 to 9) or letter
(A to F) of the option you want to set.
4. Toggle the navigation switch to select and set the value of the
chosen parameter.
5. Rotate the hex switch to another parameter number/letter in the
current bank, and then repeat step 4.
or
Rotate the hex switch to “0” again to select a different bank, and
then repeat steps 3 and 4.
Table 3-2.
Selected Bank as Indicated by Control LEDs
LED BS1
LED BS2
Bank Number
Off
Off
0
Off
Off
1
Off
On
2
Off
On
3
Note
For best results, use the
available 6800
+
software
control options (serial/local or
Ethernet/remote) to aid in
viewing, setting, and confirming
parameter values.