47
Image Vault
®
PRO Command
SMS Text Messages:
To enter a cell phone number to receive an SMS text message click a “Set” button under SMS Addresses. Enter
the phone number and select the cellular network.
Electrical Contact:
No setup is required on the Notifi cations Setup dialog. For hardware information refer to Alarm Output (Part I,
Section 3.12). This momentary contact is normally open and closes for ½ second (500 milliseconds) when activated.
Alarms
: Each alarm is independently confi gured with your choice of notifi cation options; this is why you must enter your notifi cation
options before confi guring the actual alarms.
Camera Loss Alarms:
Send an alarm when a camera signal is lost. You have the added option of grouping cameras and you may
set the “Number of Hours Between Notifi cations” to minimize nuisance alarms.
Data Stream Rules Alarms:
Setup alarms for each rule, one rule (Section 7.5) at a
time. Specify alarm frequency and the number of occurrences required in a given
period to activate.
External Inputs Alarms:
Identical to Rule driven alarms except these are based
on dry contact input triggers.
System Events Alarms:
Alerts you when the system is rebooted or if the “Copy
Video to CD” button is pressed on the front panel.
Camera Detect Alarms:
Send an alarm when a camera signal is detected. You
have the added option of grouping cameras and you may set the “Number of
Hours Between Notifi cations” to minimize nuisance alarms.