65
6
Advance Use
External Synchronization
To use this machine in external synchronization mode, connect the SYNC terminal to the GENLOCK terminal on
the CCU back. When SYNC terminal is connected to the GENLOCK terminal, the camera will automatically switch
from internal synchronization mode to external synchronization mode.
SYNC input conditions: Tri-level SYNC: 0.6 Vp-p / 75 Ω
Wiring Example
Prepare two sets comprised of a CCU and a MKC-X800 camera. Use a coaxial cable to connect the SYNC
connector on the CCU (master) and the GENLOCK connector on the CCU (slave).
CCU (master)
SYNC connecto
r
CCU (slave)
GENLOCK connector
Camera (master)
Camera (slave)