background image

TROUBLE SHOOTING

If you encounter problems with your fireplace system, the problem may be with either the fireplace itself or with the remote.  Review 

the fireplace manufacturer’s operation manual to make sure all connections are properly made.  Then check the operation of the 

remote in the following manner:

• 

Make sure all batteries are correctly installed in the transmitter. Also check that the batteries are fully charged.

• 

Check batteries in transmitter to make sure contacts are touching (+) and (-) ends of battery. Bend metal contacts in for tighter fit.

• 

Be sure receiver and transmitter are within 20 to 25-foot operating range.

• 

Keep receiver from temperatures exceeding 170º F.

• 

If receiver is installed in a tightly enclosed metal surrounding, the operating distance will be shortened.

• 

Make sure the hand-held transmitter and remote receiver are communicating properly (see LEARNING TRANSMITTER TO      

RECEIVER section).

FCC REQUIREMENTS

NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODI-

FICATIONS TO THE EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT

REV. 1-8-15 Page 6

IHP: RC-S-MODMV

P/N 900258-00 Rev. B 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you          

purchased the product.  If you cannot locate the dealer/distributor, then you must notify IHP in writing.  IHP must be

 notified of the claimed defect in writing within 90 days of the date of failure.  Notices should be directed to the IHP      

Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or 

visit our website at www.IHP.us.com

LEARNING TRANSMITTER TO RECEIVER

This transmitter has one of 1,048,576 unique security codes.  It may be necessary to program the remote receiver to “learn” the security 

code of the transmitter upon initial use, if batteries are replaced, or if using a replacement transmitter. 

• 

Make sure the receiver’s slide switch is in the 

REMOTE

 position.

• 

Press and release the 

LEARN

 button on the receiver.

• 

When you hear the “Beep”, press and hold the 

MODE

 button for about 2 seconds on the transmitter.

• 

If you not hear a beep after you press the 

LEARN

 button, check the power cord from the receiver and ensure it is plugged in and 

has power.

• 

You will then hear a series of beeps that indicate that your new transmitter has been accepted by the receiver.

Содержание RC-S-MODMV

Страница 1: ...er Time remaining before the system shuts off must be programmed 3 Mode Indicates whether the system is ON OFF or in THERMO mode 4 Set Indicates the desired SET temperature when in THERMO mode 5 Flame Indicates burner valve operational 6 Clock Indicates current time 7 Room Indicates current ROOM temperature 8 ºF Indicates degrees Fahrenheit ºC indicates degrees Celsius 9 Fan Indicates the fan is O...

Страница 2: ...stem allows the user to control the height of the flame when the gas valve is factory equipped with a flame controller Press and release the flame button to change the flame from regular to HI When the flame is switched to HI the word HI in a black box and a second flame appears in the lower right hand corner of the LCD screen When switched back to regular flame they both disappear RECEIVER The re...

Страница 3: ...SYSTEM CHECK Ensure that the pilot flame is lit Slide the 3 position button on the remote receiver to the ON position The main gas flame i e the fire should ignite Slide the button to OFF The main flame should extinguish the pilot flame will remain on Slide the button to REMOTE then press the ON button on the transmitter to change the system to on The main gas flame should ignite WIRING ELECTRONIC...

Страница 4: ...igure 1 3 LP INSTALLATIONS ONLY Mark the location of the slot in the slotted nut under cover screw G Using a flathead screwdriver turn the slotted nut exactly 2 full turns 720 degrees clockwise 4 Insert the correct plunger into the flame control solenoid BLUE NATU RAL GAS RED PROPANE See Figure 2 5 Ensure that the Flame Control Solenoid is disconnected from the remote receiver box 6 Screw the Sole...

Страница 5: ...nsmitter should be at least 12 months Check and replace all batteries Annually When operating range becomes reduced When transmissions are not received by the remote receiver If the hand held transmitter batteries measure less than 2 4 volts Both batteries in combination REV 1 8 15 Page 5 IHP RC S MODMV P N 900258 00 Rev B COMMUNICATION SAFETY TRANSMITTER C S T X This remote control has a COMMUNIC...

Страница 6: ...O OPERATE THE EQUIPMENT REV 1 8 15 Page 6 IHP RC S MODMV P N 900258 00 Rev B HOW TO REGISTER A CLAIM AGAINST WARRANTY In order for any claim under this warranty to be valid you must contact the IHP dealer distributor from which you purchased the product If you cannot locate the dealer distributor then you must notify IHP in writing IHP must be notified of the claimed defect in writing within 90 da...

Отзывы: