background image

AUTO SHUT DOWN

This remote control has an auto shut down feature incorporated into its system. When the transmitter mode is in the ON position, the 

appliance will only run for 9 hours. After that it will shut down. To reactivate the appliance, press the 

MODE

 button.

CP (CHILDPROOF) FEATURE

This remote control includes a childproof feature that allows the user to “lock-out” operations from the transmitter.

• 

To activate and de-activate the childproof feature, press and hold the 

SETTING 

button

 

behind the battery cover, for 5 seconds 

(SEE  The letters “CP” will briefly appear on the LCD screen when childproof mode is activated).

• 

“CP” will appear on the LCD screen if any button is pressed while childproof mode is engaged.

• 

When this mode is engaged, all auto settings go on without interruption (like thermostat). Only manual functions are prevented.

TRANSMITTER WALL BRACKET

The transmitter can be hung on a wall using the clip provided.

• 

Wood - Drill 1/8’’ pilot holes and install with screws provided.

• 

Plaster/Wallboard - Drill 1/4’’ holes, tap anchors in with hammer, then 

install with the screws provided.

Slide Transmitter 

down into holder

BATTERY LIFE

Life expectancy of the alkaline batteries in the transmitter should be at least 12 months.  Check and replace all batteries:

• 

Annually.

• 

When operating range becomes reduced.

• 

When transmissions are not received by the remote receiver..

• 

If the hand held transmitter batteries measure less than 2.4 volts (Both batteries in combination).

REV. 1-8-15 Page 5

IHP: RC-S-MODMV

P/N 900258-00 Rev. B 

COMMUNICATION - SAFETY - TRANSMITTER - (C/S - T/X)

This remote control has a COMMUNICATION –SAFETY function built into its software to ensure the transmitter and receiver are com-

municating normally.

In all operating modes, the transmitter sends an RF signal every fifteen minutes to the receiver indicating that the transmitter is within 

the normal operating range of 20-feet.  Should the receiver NOT receive this signal, the receiver will begin a 2-hour countdown. If the 

receiver does not receive a signal from the transmitter in 2 hours, the receiver will shut off the appliance.  The receiver will then emit a 

series of rapid “beeps” for a period of 10 seconds.  Then after 10 seconds of rapid beeping, the receiver will continue to emit a single 

“beep” every 2 seconds until a transmitter 

MODE

 Button is pressed to reset the receiver. 

INSTALLING FAN/BLOWER

OFF REMO

TE ON

LEARN

GROUND

VALV

E

FLAM

E

CONTROL

Line cord

from fan

Plug 2 or 3 prong plug fan cord directly into the 3 

prong polarized plug on back of the receiver.  This 

receptacle receiver is rated at 110/120VAC, 3AMP.

Содержание RC-S-MODMV

Страница 1: ...er Time remaining before the system shuts off must be programmed 3 Mode Indicates whether the system is ON OFF or in THERMO mode 4 Set Indicates the desired SET temperature when in THERMO mode 5 Flame Indicates burner valve operational 6 Clock Indicates current time 7 Room Indicates current ROOM temperature 8 ºF Indicates degrees Fahrenheit ºC indicates degrees Celsius 9 Fan Indicates the fan is O...

Страница 2: ...stem allows the user to control the height of the flame when the gas valve is factory equipped with a flame controller Press and release the flame button to change the flame from regular to HI When the flame is switched to HI the word HI in a black box and a second flame appears in the lower right hand corner of the LCD screen When switched back to regular flame they both disappear RECEIVER The re...

Страница 3: ...SYSTEM CHECK Ensure that the pilot flame is lit Slide the 3 position button on the remote receiver to the ON position The main gas flame i e the fire should ignite Slide the button to OFF The main flame should extinguish the pilot flame will remain on Slide the button to REMOTE then press the ON button on the transmitter to change the system to on The main gas flame should ignite WIRING ELECTRONIC...

Страница 4: ...igure 1 3 LP INSTALLATIONS ONLY Mark the location of the slot in the slotted nut under cover screw G Using a flathead screwdriver turn the slotted nut exactly 2 full turns 720 degrees clockwise 4 Insert the correct plunger into the flame control solenoid BLUE NATU RAL GAS RED PROPANE See Figure 2 5 Ensure that the Flame Control Solenoid is disconnected from the remote receiver box 6 Screw the Sole...

Страница 5: ...nsmitter should be at least 12 months Check and replace all batteries Annually When operating range becomes reduced When transmissions are not received by the remote receiver If the hand held transmitter batteries measure less than 2 4 volts Both batteries in combination REV 1 8 15 Page 5 IHP RC S MODMV P N 900258 00 Rev B COMMUNICATION SAFETY TRANSMITTER C S T X This remote control has a COMMUNIC...

Страница 6: ...O OPERATE THE EQUIPMENT REV 1 8 15 Page 6 IHP RC S MODMV P N 900258 00 Rev B HOW TO REGISTER A CLAIM AGAINST WARRANTY In order for any claim under this warranty to be valid you must contact the IHP dealer distributor from which you purchased the product If you cannot locate the dealer distributor then you must notify IHP in writing IHP must be notified of the claimed defect in writing within 90 da...