INSTALLING FLAME CONTROL SOLENOID
ALL STEPS REQUIRED FOR INSTALLATION OF THE FLAME CONTROLLER MUST BE DONE BY
A QUALIFIED GAS SERVICE TECHNICIAN
REV. 1-8-15 Page 4
IHP: RC-S-MODMV
P/N 900258-00 Rev. B
1. Using a flathead screwdriver, remove and set aside the three pressure
regulator mounting screws (A), pressure regulator tower (B), and spring
diaphragm assembly (C) and keep them in a safe place. (See Figure 1)
2. Ensure the rubber gasket (D), which is pre-fitted as part of the assembly
(E), is properly positioned and install the new pressure regulator tower
using the supplied screws (F). Tighten screws securely and remove cover
screw (G). (See Figure 1)
3. LP INSTALLATIONS ONLY: Mark the location of the slot in the slotted nut
under cover screw (G). Using a flathead screwdriver, turn the slotted nut
exactly 2 full turns (720 degrees) clockwise.
4. Insert the correct plunger into the flame control solenoid (BLUE = NATU-
RAL GAS, RED = PROPANE). (See Figure 2)
5. Ensure that the Flame Control Solenoid is disconnected from the remote
receiver box.
6. Screw the Solenoid on the to new regulator tower until it stops turning.
Then tighten the jam nut. (See Figure 2)
7. Now take the blue wires (connected to the solenoid) and attach them to
the orange wires (on the receiver). (See Figure 3)
CAUTION
TO ENSURE SAFE OPERATION, THE OUTLET PRESSURES ON BOTH
REGULAR AND HI FLAME LEVELS SHOULD BE CHECKED WITH A MA-
NOMETER IN ACCORDANCE WITH SPECIFICATIONS SUPPLIED BY THE
VALVE MANUFACTURER.
Fig. 1
Fig. 2
Fig. 3