background image

INSTALLING FLAME CONTROL SOLENOID

ALL STEPS REQUIRED FOR INSTALLATION OF THE FLAME CONTROLLER MUST BE DONE BY 

A QUALIFIED GAS SERVICE TECHNICIAN

REV. 1-8-15 Page 4

IHP: RC-S-MODMV

P/N 900258-00 Rev. B 

1.  Using a flathead screwdriver, remove and set aside the three pressure 

regulator mounting screws (A), pressure regulator tower (B), and spring 

diaphragm assembly (C) and keep them in a safe place. (See Figure 1)

2.  Ensure the rubber gasket (D), which is pre-fitted as part of the assembly 

(E), is properly positioned and install the new pressure regulator tower 

using the supplied screws (F). Tighten screws securely and remove cover 

screw (G). (See Figure 1)

3.  LP INSTALLATIONS ONLY: Mark the location of the slot in the slotted nut 

under cover screw (G). Using a flathead screwdriver, turn the slotted nut 

exactly 2 full turns (720 degrees) clockwise.

4.  Insert the correct plunger into the flame control solenoid (BLUE = NATU-

RAL GAS, RED = PROPANE). (See Figure 2)

5.  Ensure that the Flame Control Solenoid is disconnected from the remote 

receiver box.

6.  Screw the Solenoid on the to new regulator tower until it stops turning. 

Then tighten the jam nut. (See Figure 2)

7.  Now take the blue wires (connected to the solenoid) and attach them to 

the orange wires (on the receiver). (See Figure 3)

CAUTION

TO ENSURE SAFE OPERATION, THE OUTLET PRESSURES ON BOTH 

REGULAR AND HI FLAME LEVELS SHOULD BE CHECKED WITH A MA-

NOMETER IN ACCORDANCE WITH SPECIFICATIONS SUPPLIED BY THE 

VALVE MANUFACTURER.

Fig. 1

Fig. 2

Fig. 3

Содержание RC-S-MODMV

Страница 1: ...er Time remaining before the system shuts off must be programmed 3 Mode Indicates whether the system is ON OFF or in THERMO mode 4 Set Indicates the desired SET temperature when in THERMO mode 5 Flame Indicates burner valve operational 6 Clock Indicates current time 7 Room Indicates current ROOM temperature 8 ºF Indicates degrees Fahrenheit ºC indicates degrees Celsius 9 Fan Indicates the fan is O...

Страница 2: ...stem allows the user to control the height of the flame when the gas valve is factory equipped with a flame controller Press and release the flame button to change the flame from regular to HI When the flame is switched to HI the word HI in a black box and a second flame appears in the lower right hand corner of the LCD screen When switched back to regular flame they both disappear RECEIVER The re...

Страница 3: ...SYSTEM CHECK Ensure that the pilot flame is lit Slide the 3 position button on the remote receiver to the ON position The main gas flame i e the fire should ignite Slide the button to OFF The main flame should extinguish the pilot flame will remain on Slide the button to REMOTE then press the ON button on the transmitter to change the system to on The main gas flame should ignite WIRING ELECTRONIC...

Страница 4: ...igure 1 3 LP INSTALLATIONS ONLY Mark the location of the slot in the slotted nut under cover screw G Using a flathead screwdriver turn the slotted nut exactly 2 full turns 720 degrees clockwise 4 Insert the correct plunger into the flame control solenoid BLUE NATU RAL GAS RED PROPANE See Figure 2 5 Ensure that the Flame Control Solenoid is disconnected from the remote receiver box 6 Screw the Sole...

Страница 5: ...nsmitter should be at least 12 months Check and replace all batteries Annually When operating range becomes reduced When transmissions are not received by the remote receiver If the hand held transmitter batteries measure less than 2 4 volts Both batteries in combination REV 1 8 15 Page 5 IHP RC S MODMV P N 900258 00 Rev B COMMUNICATION SAFETY TRANSMITTER C S T X This remote control has a COMMUNIC...

Страница 6: ...O OPERATE THE EQUIPMENT REV 1 8 15 Page 6 IHP RC S MODMV P N 900258 00 Rev B HOW TO REGISTER A CLAIM AGAINST WARRANTY In order for any claim under this warranty to be valid you must contact the IHP dealer distributor from which you purchased the product If you cannot locate the dealer distributor then you must notify IHP in writing IHP must be notified of the claimed defect in writing within 90 da...

Отзывы: