background image

MOUNTING THE REMOTE RECEIVER
HEARTH MOUNT

• 

The remote receiver can be placed on the fireplace hearth or under the fire-

place behind the control access panel.

•  MAKE SURE THAT WHERE THE RECEIVER IS PLACED DOES NOT     

EXCEED 170ºF. IT WILL CAUSE DAMAGE TO THE PRODUCT. 

• 

Use the wires attached to the remote receiver to connect to the gas valve or 

the electric module.

• 

Be sure that the connectors do not touch each other or other bare metal 

surfaces; this will cause the appliance to turn ON. The connectors may be 

wrapped with electrical tape to prevent this.

OFF REMO

TE ON

LEARN

GROUND

VALV

E

FLAM

E

CONTROL

WIRING INSTRUCTIONS

A qualified electrician should install the remote control system.

WIRING MILLIVOLT VALVES

INSTALLATION

Before installation make sure the remote receiver slide switch is in the 

OFF

 position. After installation be sure that the slide switch is 

moved to the 

REMOTE

 position.

TERMINAL BLOCK

ON MILLIVOLT

GAS VALVES

TH

TP

TP

TH

THERMOPILE/

PILOT LIGHT

REMOTE

RECEIVER

• 

Connect one wire from the remote receiver’s “valve” connection 

to the TH terminal on the gas valve.

• 

Connect the other wire from the remote receiver’s “valve”    

connection to the TH/TP terminal on the gas valve.

MILLIVOLT SYSTEM CHECK

• 

Ensure that the pilot flame is lit.

• 

Slide the 3-position button on the remote receiver to the 

ON

 position.  The main gas flame (i.e., the fire)   

should ignite. 

• 

Slide the button to 

OFF

.  The main flame should extinguish (the pilot flame will remain on).

• 

Slide the button to 

REMOTE

, then press the 

ON

 button on the transmitter to change the system to on. The main 

gas flame should ignite.

WIRING ELECTRONIC SPARK IGNITIONS

I

S

Electronic

Module

Piggyback

Connectors

Switch

Wires

REMOTE

RECEIVER

ELECTRONIC SPARK SYSTEM CHECK

• 

Slide the 3-position button on the remote receiver to the 

ON

 position.  The spark electrode should begin sparking to ignite the pilot.  

After the pilot flame is lit, the main gas valve should open and the main gas flame should ignite.

• 

Slide the button to 

OFF

.  The main gas flame and pilot flame should both extinguish.

• 

Slide the button to 

REMOTE

, then select “ON” with the mode button on the transmitter to change the system to ON.  The spark 

electrode should begin sparking to ignite the pilot.  After the pilot is lit, the main gas valve should open and the main gas flame 

should ignite.

Take both switch/thermostatic wires from the Electronic 

Module, and connect them to the receiver wires using 

the spade connectors.

NOTE: An adaptor may be necessary to 

make the connection between the Electronic    

Module and the Remote Receiver.

REV. 1-8-15 Page 3

IHP: RC-S-MODMV

P/N 900258-00 Rev. B 

Содержание RC-S-MODMV

Страница 1: ...er Time remaining before the system shuts off must be programmed 3 Mode Indicates whether the system is ON OFF or in THERMO mode 4 Set Indicates the desired SET temperature when in THERMO mode 5 Flame Indicates burner valve operational 6 Clock Indicates current time 7 Room Indicates current ROOM temperature 8 ºF Indicates degrees Fahrenheit ºC indicates degrees Celsius 9 Fan Indicates the fan is O...

Страница 2: ...stem allows the user to control the height of the flame when the gas valve is factory equipped with a flame controller Press and release the flame button to change the flame from regular to HI When the flame is switched to HI the word HI in a black box and a second flame appears in the lower right hand corner of the LCD screen When switched back to regular flame they both disappear RECEIVER The re...

Страница 3: ...SYSTEM CHECK Ensure that the pilot flame is lit Slide the 3 position button on the remote receiver to the ON position The main gas flame i e the fire should ignite Slide the button to OFF The main flame should extinguish the pilot flame will remain on Slide the button to REMOTE then press the ON button on the transmitter to change the system to on The main gas flame should ignite WIRING ELECTRONIC...

Страница 4: ...igure 1 3 LP INSTALLATIONS ONLY Mark the location of the slot in the slotted nut under cover screw G Using a flathead screwdriver turn the slotted nut exactly 2 full turns 720 degrees clockwise 4 Insert the correct plunger into the flame control solenoid BLUE NATU RAL GAS RED PROPANE See Figure 2 5 Ensure that the Flame Control Solenoid is disconnected from the remote receiver box 6 Screw the Sole...

Страница 5: ...nsmitter should be at least 12 months Check and replace all batteries Annually When operating range becomes reduced When transmissions are not received by the remote receiver If the hand held transmitter batteries measure less than 2 4 volts Both batteries in combination REV 1 8 15 Page 5 IHP RC S MODMV P N 900258 00 Rev B COMMUNICATION SAFETY TRANSMITTER C S T X This remote control has a COMMUNIC...

Страница 6: ...O OPERATE THE EQUIPMENT REV 1 8 15 Page 6 IHP RC S MODMV P N 900258 00 Rev B HOW TO REGISTER A CLAIM AGAINST WARRANTY In order for any claim under this warranty to be valid you must contact the IHP dealer distributor from which you purchased the product If you cannot locate the dealer distributor then you must notify IHP in writing IHP must be notified of the claimed defect in writing within 90 da...

Отзывы: