Pastry Cases
5.1 Cleaning and maintenance
All maintenance service needs to be performed after disconnecting the
equipment from the power supply!
Protect electric installation against any damage or water spillage.
Do not use water stream to clean the equipment, only a moist cloth.
Do not use any sharp objects to remove dirt!
When cleaning inside of the device do not leave the front glass panel lifted in the
aluminum profile. This may cause damage to the glass and is not covered by
warranty. Please remove the glass with profile during cleaning. (Figure 6)
When using the display case, as well as during maintenance work, pay attention not
to damage the temperature sensor!
It is recommended to make a break in the operation
once a month
in order to clean the interior, naturally defrost
the evaporator and clean the condenser.
It is essential to keep the condenser of the device clean. Dirt may hinder the heat exchange, causing increase in
electricity consumption and may cause damage of the compressor. In order to clean the condenser it is necessary
to unscrew the sheet metal screws and pull the wind brace out of catch by lifting it up. Clean condenser lamellas
with help of soft brush or paint brush. If the condenser is extremely dirty (blocking of lamellas), use vacuum
cleaner or compressed nitrogen to remove dirt from between lamellas.
Figure 6 Disassembly of the front glass (JSCRP)
1 – Front glass
2 – Upper aluminum profile (lifted guide) of the glass
3 – Lower aluminum profile (hinge) of the glass