REFRIGERATION LTD 

 

Pastry Cases

 

| www.igloorefrigeration.com

 

11 

 

c0 

compressor and fan start delay on power-up 

min 

100 

c1 

minimum time between consecutive compressor starts 

min 

100 

c2 

minimum compressor off time 

min 

100 

c3 

minimum compressor on time 

min 

100 

c4 

compressor on time with duty setting 

50 

min 

100 

cc 

continuous cycle duration 

15 

c6 

temperature alarm bypass after continuous cycle 

15 

d0 

type of defrost 

dI 

interval between defrosts 

199 

dt 

end defrost temperature set point 

12.0 

°C 

-50 

130 

dP 

maximum defrost duration 

60 

min 

199 

d4 

defrost when switching the instrument on 

d5 

defrost delay on power-up or when enabled by digital input 

min 

199 

d6 

freeze control temperature display during defrost 

dd 

dripping time 

min 

15 

d8 

alarm bypass time after defrost 

15 

d9 

defrost priority over compressor  protectors 

d/ 

defrost probe reading (2) 

°C 

dC 

time base 

A0 

alarm and fan temperature differential 

2.0 

°C 

-20 

+20 

AL 

absolute/relative temperature for low temperature alarm 

0.0 

°C 

-50 

+99 

AH 

absolute/relative temperature for high temperature alarm 

0.0 

°C 

-50 

+99 

Ad 

temperature alarm delay 

min 

199 

A4 

3rd input configuration 

11 

A7 

digital input alarm delay 

min 

199 

A8 

enable alarm “Ed” (end  defrost  by timeout) 

AC 

set point dirty condenser alarm 

60 

°C 

-50 

250 

AE 

dirty condenser alarm differential temperature 

3.0 

°C 

0.1 

20 

Acd 

dirty condenser alarm delay 

min 

250 

H0 

serial address 

207 

H1 

AUX output configuration 

H2 

enable keypad 

H4 

disable buzzer 

 

H5 

ID code (read-only) 

+199 

EZY 

restore the Default settings 

5. MAINTENANCE 

 

Before you start Maintenance on the unit, Power it 

OFF.

 

 

Do not use steel wool, abrasive cleaners, bleach or cleaners containing chlorine or sodium to clean the unit. 

 

Do not use a pressure washer or water-jet to clean the unit. 

 

The unit should be cleaned right after unpacking and before turning it on. 

 

The unit should be cleaned with warm water and a mild soap. 

 

Make sure to cover the fan motor to prevent moisture damage. 

 

Door gaskets, shelves and supports should be cleaned on a regular basis. 

 

Fan blades and guards should be cleaned with a soft cloth. 

Содержание J2SCRP

Страница 1: ...Pastry Display Cases Models JSCRP and J2SCRP JSCRP J2SCRP Instruction Manual Tel 416 663 3051 Fax 416 663 5793 Toll Free 1 888 408 8819 124 Norfinch Dr Toronto ON M3N 1X1 REFRIGERATION LTD ...

Страница 2: ...1 Temperature regulation 8 5 MAINTENANCE 9 5 1 Cleaning and maintenance 12 6 SERVICE 13 6 1 Faults identification and repair 13 6 2 Service 14 List of Figures Figure 1 JSCRP and J2SCRP 4 Figure 2 Leveling legs 6 Figure 3 Mounting wire shelves 6 Figure 4 Control panel 7 Figure 5 Carel thermostat control panel 8 Figure 6 Disassembly of the front glass JSCRP 12 Figure 7 Cleaning the condenser 13 List...

Страница 3: ...on the environment and the location of the unit 2 2 Description of the unit JSCRP and J2SCRP display cases have static cooling The display case is equipped with automatic condensate evaporation and automatic defrosting The electronic thermostat cooperate module to monitor and send signals when the temperature inside the equipment gets too low or too high Two levels of white plastic wire shelves ar...

Страница 4: ... louver 10 ABS sides 11 Control panel 12 Condenser cover DO NOT BLOCK air louver 13 Leveling legs 14 Serial plate 15 Straight front glass 2 3 Technical data Table 1 Technical data Model Voltage V Hz Ph Rated Current A Max shelf load lbs kg Weight lbs kg JSCRP4 J2SCRP4 115 60 1 8 max fuse 15 66 30 337 153 JSCRP6 J2SCRP6 115 60 1 8 max fuse 15 66 30 529 240 JSCRP8 J2SCRP8 115 60 1 15 max fuse 20 66 ...

Страница 5: ...ay be turned on after confirmation of the fire protection efficiency with results of measures performed according to binding regulations 3 2 Unit Location Remove cardboard angles and protective foil Install the unit on a strong and level surface To ensure proper operation the unit must be leveled from front to back and left to right Unit may malfunction if improperly leveled Be sure there is suffi...

Страница 6: ... disassembled If the user received the unit partially disassembled perform the following operations 1 Place the Fixed shelf grip in perforated frame strip Figure 3 5 2 Mount cross bars Figure3 3 and Figure 3 4 3 Place shelves on fixed grips 4 Mount front glass of the display case The equipment should be cleaned right after unpacking and before turning the unit on The unit should be cleaned with wa...

Страница 7: ...nd aggregate operating cycle may fluctuate This depends on numerous factors such as amount and temperature of products placed in the device and the temperature of the surroundings The equipment should be placed in a dry and well ventilated place ensuring proper air exchange distance between the wall and the equipment min 10cm out of sunlight kept far from heat sources and devices enforcing air flo...

Страница 8: ...rranty Do not use electric devices inside the product storing chamber Avoid unnecessary opening of doors and leaving them open for a longer period of time 4 1 Temperature regulation The thermostat is to obtain the set temperature within the equipment and maintain it within the determined temperature ranges The manufacturer enters all settings of temperature regulators required for normal functioni...

Страница 9: ... 1 sec displays sets the set point more than 3 sec accesses the parameter setting menu enter password 22 mutes the audible alarm buzzer Start Up hold the set mute button for 1 sec RESET current EY set Pressed together 7 and 8 activate parameter reset procedure Diode 8 Defrost Pressing this button alone more than 3 sec activates deactivates the defrost Pressing with other buttons pressed together w...

Страница 10: ...he category of parameters will be on Press SET to display the value associated with the parameter Increase or decrease the value using the UP or DOWN button respectively Press SET to temporarily save the new value and display the parameter again Repeat the procedure for any other parameters that need to be modified Press the SET button for more than 3 s to permanently save the parameters and exit ...

Страница 11: ... absolute relative temperature for low temperature alarm 0 0 C 50 99 AH absolute relative temperature for high temperature alarm 0 0 C 50 99 Ad temperature alarm delay 0 min 0 199 A4 3rd input configuration 0 0 11 A7 digital input alarm delay 0 min 0 199 A8 enable alarm Ed end defrost by timeout 0 0 1 AC set point dirty condenser alarm 60 C 50 250 AE dirty condenser alarm differential temperature ...

Страница 12: ... attention not to damage the temperature sensor It is recommended to make a break in the operation once a month in order to clean the interior naturally defrost the evaporator and clean the condenser It is essential to keep the condenser of the device clean Dirt may hinder the heat exchange causing increase in electricity consumption and may cause damage of the compressor In order to clean the con...

Страница 13: ... equipment is not working Make sure that The equipment is connected to the power supply The Voltage and frequency in the network are compliant with those recommended by the manufacturer 115V 60Hz The main switch is turned on The Thermostat is turned on The equipment is operating but the light is off Make sure that Light switch is turned on Lamp or starting switch of the equipment is not burnt Wate...

Страница 14: ... Each compressor makes certain noises when operating These sounds are made by the aggregate engine and by cooling agent flowing through the circuit This phenomenon constitutes a technical feature of cooling devices and does not signify equipment failure Steam precipitation on glass is normal in event of high relative air humidity exceeding 55 and does not require calling for service 6 2 Service IG...

Отзывы: