NAVAIR 17—2OAX—737
CALIBRATION CHECKLIST
TEST
INST
~
IFR Inc. NAV- 750, NAV-750A, and NAV—750B VOR/LOC/COMM and 0/S Bench Test Sets
PROC. NO.
NA 17-2OAX-737
MFG.
MODEL
SER. NO.
PROCEDURE
STEP
NO.
(1)
FUNCTION TESTED
(2)
NOMINAL
(3)
MEASURED VALUES
OUT
OF
TOL
~
CALIBRATION TOLERANCES
(7)
FIRST RUN
(4)
SECOND RUN
(5)
4.9
VOR Bearing Tests
—
494
TO 0°
00°
000 00° ÷005°
496
FROM 0°
180 0°
180 00° ÷005°
498
TO 180°
1800°
“
4910
FROM 180°
00°
00000° ÷005°
4912
T090°
900°
9000°÷005°
4.9.14
FROM 90°
270.0°
270.00°±0.05°
4.9.16
TO 270°
“
“
4.9.18
FROM 270°
90.0°
90.00°±0.05°
4.10
LOC Centering Test
4.10.3
150 Hz DEMOD voltage
NA
Record
4.10.5
90 Hz DEMOD voltage
NA
Record
4.10.6
Difference
Diff <2.75 mV rms
4.11
G/S Centering Test
4.11.2
150 Hz DEMOD voltage
NA
Record
4.11.4
90 Hz DEMOD voltage
NA
Record
4.11.5
Difference
Diff <2.75 mV rms
4.12
Spectral Purity Tests (NAV—75( only)
(MHz)
(Harmonics)
4.12.4
108.000
— —
ck
()
>30 dBc
115.000
——
ck
()
130.000
— —
ck()
“
“
145.000
— —
ck
()
“
“
157.000
— —
ck
()
“
4.12.6
329.000
— —
ck ()
“
“
332.000
— —
ck ()
“
“
335.000
— —
ckfl
“
Page 6
of
8
34