NAVAIR 17—2OAX—737
CALIBRATION CHECKLIST
TEST
INST
~
IFR Inc. NAV—750, NAV—750A, and NAV—750B VOR/LOC/COMM and G/S Bench Test Sets
PROC. NO.
NA 17-2OAX-737
MFG.
MODEL
SER. NO.
PROCEDURE
STEP
NO.
(1)
FUNCTION TESTED
(2)
NOMINAL
(3)
MEASURED VALUES
OUT
CALIBRATION TOLERANCES
(7)
FIRST RUN
(4)
SECOND RUN
(5)
OF
TOL
~
4.7.30
30% AM
—
1020 Hz
30.0%
—
28.8%
to
31.2%
4.7.34
95%
AM
—
400 Hz
95.0%
92.15% to
97.85%
4.7.35
0—100 Meter Scale
——
ck
()
—
±3.0%(AM) of step 4.7.34
4.7.37
95% AM
—
1300 Hz
95.0%
—
92.15% to
97.85%
4.7.40
95% AM
—
3000 Hz
95.0%
92.15% to
97.85%
4.8
RF
Level Meter Tests
(MHz)
(needle widths)
4.8.2
108.000
——
ck
()
within ±1.5
4.8.4
110.000
——
ck
()
—
—
“
“
130.000
——
ck()
“
“
150.000
——
ck
()
—
—
“
“
170.000
——
ck
()
—
“
“
190 000
——
ck
()
“
“
210.000
——
ck()
—
“
“
230.000
——
ck
()
—
“
“
250.000
——
ck
()
“
“
270.000
——
ck
()
—
—
“
“
290.000
——
ck
()
“
“
310.000
——
ck()
—
“
“
330.000
——
ck
()
—
“
“
335.000
——
ck()
—
—
“
4.8.7*
72.000
——
ck
()
—
“
4.8.8*
74.000
——
ck
()
—
“
4.8.8~
76.000
——
ck
()
—
“
78.000
——
ck
()
“
*
Applicable only if TI is a NAV—750B.
Page 5
of
8
33