NAVAIR 17—2OAX—737
CALIBRATION CHECKLIST
TEST INST (S)
IFR Inc. NAV-750, NAV-750A, and NAV-750B VOR/LOC/COMM and G/S Bench Test Sets
PROC. NO.
NA 17-2OAX-737
MFG.
MODEL
SER. NO.
PROCEDURE
STEP
NO.
(1)
FUNCTION TESTED
(2)
NOMINAL
(3)
MEASUPFD VALUES
°~
TOL
(6)
CALIBRATION TOLERANCES
(7)
FIRST RUN
(4)
SECOND RUN
(5)
(V dc)
(mV dc)
4.4.3.17
DC offset
0.0
—40.0
to
+40.0
4.4.3. 19
1020 Hz tone
——
ck
()
NA
Displayed
“
(V dc)
(mV dc)
“
0.0
—
—40.0
to
÷40.0
4.4.3.22*
400 Hz tone
——
ck
()
NA
Displayed
“
(V dc)
(mV dc)
“
DC
offset
0.0
—80.0
to
÷80.0
4.4.3.24*
1300 Hz tone
——
ck
()
NA
Displayed
“
(V dc)
(mV dc)
“
DC offset
0.0
—
—80.0
to
+80.0
4.4.3.26*
3000 Hz tone
——
ck
()
NA
Displayed
“
(V
dc)
—
(mV dc)
“
DC
offset
0.0
—80.0
to
+80.0
4.5
Tone Frequency Tests
(Hz)
(Hz)
—
—
(Hz)
4.5.3
30 REF
30.0
29.994
to
30.006
4.5.6
90
90.0
—
89.982
to
90.018
4.5.8
90
90.0
“
(Hz)
(Hz)
—
(Hz)
4.5.10
150
150.0
149.97
to
150.03
4.5.12
150
150.0
“
(p.s)
—
(p.s)
4.5.18
9960 Hz deviation
48.5
46.1
to
50.9
(Hz)
(Hz)
—
(Hz)
4.5.19
9960
9960.0
9958.008
to
9961.992
4.5.22
30 Variable
30.0
—
29.994
to
30.006
4.5.24
1020
1020.0
1014.9
to
1025.1
*Applicable only if TI is a NAV—750B.
Page 3 of 8
31