5 Mounting
In order to expose the module to the minimum mechanical stress it should pre-
ferably be mounted horizontally or vertically on the mounting panel� The module
must be fixed with four screws to DIN 7500 or DIN 7984 (M5 x L)�
If possible, the module should be mounted in such a way that the cable entry of
the plug points downwards�
As the self-heating of the electronics of the unit is dissipated via the housing, suffi-
cient cooling must be ensured in case of "sandwich mounting" of modules�
6 Electrical connection
To ensure the protection of the device against electrical interference and the
safe function of the device, the housing must be connected to the ground of
the vehicle�
1: Drill hole for ground connection
►
Establish a connection between the device and the ground of the vehicle using
M5 screws�
►
To protect the whole system (wiring and module) the individual electric circuits
must be protected�
Designation
Potential
Pin No.
Fuse
Operating voltage sensors/module
VBB
S
23
2 A
Operating voltage outputs
VBB
O
05