UK
SmartModul CR2512
23
Index
S-Idx
Designation
Type
Default
Description
1801
5
Event timer
Trans PDO 2
u16,rw
0x00
Max� transfer break
in trans type "asynch",
when this time has elapsed the PDO is
transferred even if the appl� event has
not occurred�
1A00
0
Mapping Trans
PDO 1
u32, ro
0x01
Number of the linked application objects
(binary inputs)
1A00
1
Index in the
object
directory
u32, ro
0x600 01
Idx 6000, Sldx 01 contains 1 byte
0b 0000 0001 channel 9 (input 1)
0b 0000 0010 channel 10 (input 2)
0b 0000 0100 channel 11 (input 3)
0b 0000 1000 channel 12 (input 4)
1A01
0
Mapping Trans
PDO 2
u32, ro
0x01
Number of the linked application objects
(actual current values)
1A01
1
Index in the
object directory
u32, ro
0x2002 01
0x2002 02
0x2002 03
0x2002 04
Idx 2002, SIdx 01 contains the actual
current value channel 1/2
Idx 2002, SIdx 02 contains the
actual current value channel 3/4
Idx 2002, SIdx 03 contains the
actual current value channel 5/6
Idx 2002, SIdx 04 contains the
actual current value channel 7/8