5 Structure and operating principle
5.1 Indicators and connections
A1
Supply voltage (L-, L+), function terminals (Y1, Y2)
A2
Y4, Y5, Y6, Y7: Operating mode selection, auxiliary output
A3
S33, S34, S43, S44: Connection for safety inputs / outputs
K 1
LED yellow: Triggering of the relay output channel 1
K 2
LED yellow: Triggering of the relay output channel 2
E 1
LED yellow: Input signal channel 1 or TE (for clocked sensor)
E 2
LED yellow: Input signal channel 2 or A (for clocked sensor)
Power
LED green: Voltage supply
Fault
LED red: Fault/start-up
C1
13, 14: Connection of relay output without delay, 1 x normally open (closed
when enabled)
C2
23, 24: Connection of relay output, 1 x normally open (closed when
enabled)