background image

Drive Goods 

Relay Terminal Block with Brake Contact Output 

Model Name 

DG2BK1TB-

-

 

User’s Manual 

Before Using the Product 

Thank you for purchasing these Drive Goods product. 
Before using the product, this document and our MEEFAN homepage obtain 
the User

’s Manual of the publication, and please read the following items. 

           

  SAFETY PRECAUTIONS 

           

  FOR YOUR SAFETY 

Please read the User

’s Manual of the homepage publishing, and use details 

correctly after understanding the function and the performance of this product 
enough. 

 

MEEFAN homepage    URL     

http://www.mee.co.jp/sales/fa/meefan/ 

 

● SAFETY PRECAUTIONS ● 

(Always read these precautions prior to use.) 

Do not attempt to install, operate, maintain, or inspect this product until you have carefully read through 
this instruction manual and relevant documents and can use the equipment correctly. Do not use this 
product until you have a full knowledge of the equipment, safety information, and instructions. In this 
manual, the safety instruction levels are clas

sified into "WARNING" and "CAUTION.” 

 

 

  

 

WARNING 

 

Indicates that incorrect handling may cause hazardous conditions, 
resulting in death or severe injury. 

 

 

 

 

 

CAUTION

 

 

Indicates that incorrect handling may cause hazardous conditions, 
resulting in minor or moderate injury or property damage. 

 

 

  

 
Under some circumstances, failure to observe the precautions given under "

CAUTION" may lead to 

serious consequences. Observe the precautions of both levels because they are important for personal 
and system safety. 
After reading this manual, keep the manual in a safe place for future reference. 

1. Electric Shock Prevention 

  WARNING 

  Make sure that all wiring work and inspections are performed by professional engineers. 

  Do not damage, apply unreasonable stress to, place heavy objects on, or pinch the cables. Doing so 

results in the risk of electric shock. 

  To avoid electric shock, insulate the connection area of the power supply terminal. 

  Be sure to shut off all phases of the external power supply used by the system before performing work 

such as installation and wiring. Failure to do so results in the risk of electric shock and product damage. 

2. Fire Prevention 

  CAUTION 

  Be sure to install this product in a non-flammable object. Directly installing the product in a flammable 

object or installing the product near a flammable object results in the risk of fire. 

  Do not allow any conductive foreign objects, such as a screw or metal fragments, or flammable foreign 

objects, such as oil, to enter the product interior. 

3. Injury Prevention 

  CAUTION 

  Be careful to connect terminals correctly. Failure to do so results in the risk of explosion, damage, and 

the like. 

  Do not mistaken the polarity (positive and negative charges). Doing so results in the risk of explosion, 

damage, and the like. 

4. General Precautions 

Also note the following precautions. Incorrect handling may cause failure, injury, electric shock, and the 
like. 

(1) Transport and Installation 

  CAUTION 

  This product is a precision instrument. During transport, avoid impacts larger than those specified in 

general specifications. Failure to do so results in the risk of failure. 

  Do not stand or rest heavy objects on the product. 

  Do not install or operate units that are damaged or have missing parts. 

  This product is a precision instrument. Do not drop or apply strong impact to the product. 

 

Use this product in an environment that reflects the general specifications set forth in the User’s Manual. 
Usage in an environment outside of the scope of the general specifications results in the risk of electric 
shock, fire, malfunction, product damage, and/or product deterioration. 

  When handling the product, be careful of sharp areas such as product corners. 

  Be sure to place this product inside a metal control panel. 

  Reliably secure the module using a DIN rail or screws. If the module is not properly mounted, risk of 

malfunction, failure, and falling results. If using the product in an environment with high vibration, secure 
the product with screws. 

  Tighten the screws within the specified torque range. Loose screws results in the risk of falling, a short 

circuit, and malfunction. Excessively tightened screws may damage the screws and product, resulting in 
the risk of falling, a short circuit, and malfunction. 

  Fumigants that contain halogen materials such as fluorine, chlorine, bromine, and iodine used for 

disinfecting and protecting wooden packaging from insects will cause malfunction in Mitsubishi Electric 
Engineering products. Please take necessary precautions to ensure that residual fumigants do not enter 
the product, or treat packaging with methods other than fumigation (heat method, etc.). Additionally, 
disinfect and protect wood from insects before packing. 

(2) Wiring 

 

CAUTION 

  This product is a Mitsubishi Electric general-purpose AC servo amplifier MR-J4-B and MR-J3-B series 

dedicated product. Do not use the product with any servo amplifier or servo motor with an 
electromagnetic break other than the MR-J4-B and MR-J3-B series. 

  Be sure to wire the product correctly. Failure to do so results in the risk of unexpected servo motor 

operation. 

  The connection drawings in this manual are based on a sink interface, unless otherwise specified. 

  Be careful to properly set the orientation of the diodes for surge absorption, which are attached to the 

DC relay for servo amplifier control signal output signals. Incorrect orientation results in the risk of the 
servo amplifier failure, which can cause signal output failure and malfunction of protective circuits such 
as emergency stop. 

 

 

  Always verify that the wiring is properly secured to the terminal block. Failure to adequately secure the 

wiring results in the risk of poor contact, which can cause heat generation from the wiring and terminal 
block. 

  Properly connect the wiring to the module after first verifying the module rated voltage and terminal 

layout. Inputting or connecting the power supply to voltage that differs from the rated voltage and 
miswiring result in the risk of fire and product failure. 

  Securely install the connector to the module. Failure to do so results in the risk of malfunction. 

  Be sure that foreign matter such as dust and wire shavings does not enter the module interior. Failure to 

do so results in the risk of fire, failure, and malfunction. 

 

  CAUTION 

  Be sure to secure the power lines and cables connected to the module by placing them in a duct or 

clamping them. If not, dangling cables may swing, move, or inadvertently be pulled, resulting in damage 
to the module or cables, or malfunction due to poor cable connection. 

  When disconnecting the cable connected to the module, do not pull the cable by the cable part. For 

cables with connectors, take hold of the connector connected to the module and then disconnect the 
connector. For cables connected to the terminal block, unlock the terminal board spring lock and then 
disconnect the connector. Pulling the connected cable may result in malfunction or damage to the 
module or cable. 

  When connecting the servo amplifier, first verify that the product configuration is correct. Connecting the 

servo amplifier with a wrong configuration results in the risk of failure and malfunction. 

  Securely mount the relay module to the module. Incorrect mounting results in the risk of damage, falling, 

and malfunction due to poor contact. Additionally, be sure to attach and detach the relay module 
following the correct procedure. Failure to do so results in the risk of damage, falling, and malfunction 
due to poor contact. 

(3) Usage 

  CAUTION 

  Do not disassemble, repair, or modify the product. 

  Never attempt to burn or disassemble the product. Doing so may cause generation of a poisonous gas. 

  Be careful when changing the output device assignments in servo amplifier parameters. Changing the 

MBR (electromagnetic brake interlock) signal assignments, in particular, may cause unexpected 
operation of the servo motor, damage, falling, and malfunction. 

  Make sure to set up external safety circuits outside the product to ensure safe system operation even 

during external power supply problems or servo amplifier or product failure. Otherwise, erroneous output 
or malfunction may cause serious accidents. 

  Relay or other similar failure may cause output to remain ON or OFF. Be sure to provide a circuit outside 

the product that monitors output signals that may lead to serious accidents. 

  When a load current exceeding the current rating or an overcurrent caused by a load short-circuit flows 

for a long time, it may cause smoke and fire. To prevent this, provide an external safety circuit. 

(4) Emergency Handling 

 

CAUTION 

  Connect the emergency stop switch to the EMG1 terminal and EMG2 terminal to ensure that the 

electromagnetic brake activation output is linked to the external emergency stop switch. 

 
 
 
 
 

(5) Maintenance and Inspection 

  CAUTION 

  Before removing or installing the module, cut off all phases of the power supply externally. Failure to do 

so may cause module failure, malfunction, or damage. 

  Connection/disconnection of the module and cables after the first use of the product shall be limited to 

50 times. (JIS B 3502 compliant) 

  Before handling the module, touch a grounded metal object to discharge the static electricity from your 

body. Failure to release the static electricity may cause the module to fail or malfunction. 

(6) Disposal 

  CAUTION 

  When disposing of this product, treat it as industrial waste. 

 

 

1.  Over view 

 

This User’s Manual describes the specifications of the relay terminal block with brake contact 
output that is used in combination with the Mitsubishi Electric general-purpose AC servo amplifier 
MR-J4-B series and MR-J3-B series. 

 

2.  GENERAL SPECIFICATIONS 

 

 

Item 

Environment Conditions 

Ambient 
temperature 

Operating 

0°C to 55°C (non-condensing) 

Storage 

-20°C to 65°C (non-condensing) 

Ambient 
humidity 

Operating 

90% RH or less (non-condensing) 

Storage 

Environment 

Indoors (not exposed to direct sunlight), free of corrosive gas, combustible 

gas, oil mist, and dust 

Elevation 

Within 1000m above sea level 

Vibration resistance 

5.9m/s

2

, 10Hz to 55Hz (X, Y, and Z directions) 

 

 

3.  PERFORMANCE SPECIFICATIONS 

 

 

Model name 

DG2BK1TB DG2BK1TB-D KG2BK1TB-P01 DG2BK1TB-P01-D 

Connected servo amplifier 

MR-J4-B series, MR-J3-B series 

Compatible servo motor capacity 

0.05kW to 22kW 

Servo amplifier interface connector 

MDR20P connector 

Control logic 

Sink logic 

Source logic 

External 

signal relay 

terminal 

block 

Terminal area 

Recommended tool: SZF0-0, 4x2, 5 (Phoenix Contact) or 

equivalent product 

No. of terminals: 11P, 3.5-mm pitch, No. of line insertions: 1 per 

insertion port 

Compatible wiring 

Single wire, base wire: 0.2mm

2

 to 1.5mm

2

, AWG24 to AWG16 

Brake output 

terminal 

block 

Terminal area 

Recommended tool: SZF0-0, 4x2, 5 (Phoenix Contact) or 

equivalent product 

No. of terminals: 6P, 3.81-mm pitch, No. of line insertions: 

1 per insertion port 

Compatible wiring 

Single wire, base wire: 0.2mm

2

 to 1.5mm

2

, AWG24 to AWG16 

External 

power supply 

For servo amplifier interface 

Voltage: 24 VDC ± 10%, Current capacity: 0.3A (max) 

For electromagnetic brake 

Voltage 24 VDC 0/-10%, Current capacity 1.43A (max) 

MBR signal 

relay 

Response 

time 

OFF

ON 

10ms or less 

ON

OFF 

5ms or less 

Mechanical service life 

50 million times or more (switch frequency: 180 times/minute) 

Electrical service life 

100,000 times or more (resistance load) 

Operation display 

LED illumination display at relay coil ON 

Socket 

Yes (relay module replaceable) 

Overseas 
compliant 
standards 

UL standards 

UL61800-5-1 

Module installation 

Screw/ 

DIN rail 

DIN rail 

Screw/ 

DIN rail 

DIN rail 

Installation 

screws 

Screw size 

M4 x 0.7mm 

x 10mm or 

greater 

M4 x 0.7mm x 

10mm or 

greater

 

Tightening torque 

78 to 

118N

cm 

78 to 118N

cm 

Compatible DIN rail 

TH35-7.5Fe, TH35-7.5Al (JIS C2812 compliant) 

Weight 

Approx. 57g  Approx. 56g 

Approx. 57g 

Approx. 56g 

 

Relay terminal block with brake 

contact output 

 

DOCOM 

Control output 
signal 

24 VDC 

 

RA

 

With sink output interface 

Connect the emergency stop switch 

Relay terminal block with brake 
contact output 

24V 

0V 

B1 

B2 

EMG1 

EMG2 

TE2 

24 VDC 

Servo motor 

Electromagnetic 
brake 

 

DOCOM 

Control output 
signal 

24 VDC 

Relay terminal block with brake   

contact output 

RA

 

With source output interface 