ENGLISH
INPUT
/
OUTPUT MODULE
CR2513
PAGE
35
Object directory
Manufacturer-specific profile area; index 2000 to 5FFF
Index
S-idx
Designation
Type
Default
Description
2000
0x00
I/O configuration
u8, rw
0x0C
number of the entries
= number of the I/O channels
0x01
configuration
u8, rw
0x02
configuration channel 1
channel 1
0 = OFF
2 = binary output
4 = analog output (PWM)
8 = analog output (Danfoss valve
triggering via RC low-pass filter)
0x02
configuration
u8, rw
0x02
configuration channel 2
channel 2
0 = OFF
2 = binary output
4 = analog output (PWM)
8 = analog output (Danfoss valve
triggering via RC low-pass filter)
0x03
configuration
u8, rw
0x02
configuration channel 3
channel 3
0 = OFF
2 = binary output
4 = analog output (PWM)
8 = analog output (Danfoss valve
triggering via RC low-pass filter)
0x04
configuration
u8, rw
0x02
configuration channel 4
channel 4
0 = OFF
2 = binary output
4 = analog output (PWM)
8 = analog output (Danfoss valve
triggering via RC low-pass filter)
0x05
configuration
u8, rw
0x01
configuration channel 5
channel 5
0 = OFF, 1 = binary input
0x06
configuration
u8, rw
0x01
configuration channel 6
channel 6
0 = OFF, 1 = binary input
0x07
configuration
u8, rw
0x01
configuration channel 7
channel 7
0 = OFF, 1 = binary input
0x08
configuration
u8, rw
0x01
configuration channel 8
channel 8
0 = OFF, 1 = binary input
0x09
configuration
u8, rw
0x03
configuration channel 9
channel 9
0 = OFF
3 = analog input (voltage)
0...10,000 mV
6 = analog input (ratiometric)
((U
IN
– ½U
B
) ÷ ½U
B
) x 1000‰
7 = analog input (current)
0...20,000
µ
A
0x0A
configuration
u8, rw
0x03
configuration channel 10
channel 10
0 = OFF
3 = analog input (voltage)
0...10,000 mV
6 = analog input (ratiometric)
((U
IN
– ½U
B
) ÷ ½U
B
) x 1000‰
7 = analog input (current)
0...20,000
µ
A