Technical data
INPUT
/
OUTPUT MODULE
CR2513
PAGE
28
Housing
Dimensions (l x w x h)
Mounting
Connection
Inputs
Outputs
can be configured as
Operating voltage U
B
Overvoltage
Current consumption
Operating temperature
Storage temperature
Protection
Interface
Baud rate
Communication profile
Node ID (default)
Status LED
Test standards
and regulations
Humidity
Mechanical resistance
Immunity to
conducted interference
Immunity to interfering
fields
Interference emission
closed screened metal housing with flange fastening
132 x 43 x 153 mm
by means of 4 M5 x L screws to DIN 7500 or DIN 7984
mounting position horizontal or vertical to the mounting wall
55-pin connector, latched, protected against reverse polarity
type AMP housing or Framatome
AMP junior timer contacts, crimp connection 0.5/2.5 mm
2
4 digital; for positive switching sensor signals (Low Side)
4 analog; choice of absolute (0...10 V / 0...20 mA)
or ratiometric for potentiometric signal transmitters
4
digital, positive switching (High Side)
analog, (PWM frequency 20...250 Hz)
incl. RC low-pass filter outputs for Danfoss valves (type PVEH/S/M)
(see also "Characteristics of the inputs/outputs", page 31)
10 ... 30 V DC SELV
36 V for t
≤
10 s
≤
100 mA (without external load)
-40°C ... +85°C
-40°C ... +90°C
IP 67 (for inserted plug with individually sealed cores e.g. EC2084)
CAN interface 2.0 B, ISO 11898
10 Kbits/s ... 1 Mbits/s (default 125 Kbits/s)
CANopen, CiA DS 301 version 3.0, CiA DS 401 version 1.4
hex20 (= 32)
two-colour LED (red/green)
≤
90 % rel. humidity, non-condensing, to IEC 68-2-30
vibration to IEC 68-2-6
shock to IEC 68-2-27
bump to to IEC 68-2-29
to DIN 40839/part 1, pulses 1, 2, 3a, 3b (corresponds to ISO 7637)
severity level 4, function state C, A
to DIN 40839/part 1, pulses 5 (corresponds to ISO 7637)
severity level 1, function state C
to DIN 40839/part 3, pulses 1, 2, 3a, 3b (corresponds to ISO 7637)
severity level 4, function state A
guideline 95/54/EC to EN 50082-2
guideline 95/54/EC to EN 50081-1