User manual
DUM1017795-EN
15
7. Installation
Visual inspection
Before switching on the power, check that the charging station has not suffered any damage during transport.
If there is any sign of damage, do not connect the charging station to the input power supply.
To do so would lead to a risk of electric shock and injury.
Upstream protection of charger power circuit
It is imperative to have protection of the upstream power circuit by the following electrical equipment:
• a 100A C-curve MCB,
• an RCD.
The customer is responsible for the design of the electrical installation and the choice of protection devices.
The customer must ensure the coordination of the protective devices with the charger.
All external circuits connected to your product must be of the Very Low Voltage (SELV) type and be Limited Pow-
er Sources less than 15VA and meeting the requirements of Chapters 2.2 and 2.5 of the standards IEC60950-1:
2005 + / A1: 2010 + / A2: 2013 and EN60950-1: 2006 + / A11: 2009 + / A1: 2010 + / A12: 2011 + / A2: 2013.
Electrical connection
The charger is equipped with a power cable ref. FLPLA018196 or FLPLA018900 which connects to the rear pan-
el.
I
WARNING
RISK OF ELECTRIC SHOCK, INJURY, AND/OR BURNING
• Incorrect connection of the grounding conductor can result in a risk of electric shock.
• This equipment shall be installed, adjusted, and serviced by qualified electrical personnel
familiar with the construction and operation of this type of equipment and associated
hazards.
Failure to follow these instructions can result in death or serious injury