User manual
DUM1017795-EN
25
Starting a charge in Combo
Connect the charging cable to the vehicle (secure firmly).
→
The LED “CHARGER READY” ❹ flashes.
The charger waits to communicate with the vehicle.
Vehicle connected
Wait for EV communication
Communication in progress…
Communication has been established.
Then the charger performs the insulation test.
INSULATION TEST...
INSUL. TEST COMPLETED
successfully
9
If there is an insulation failure:
Cancel charge...
INSULATION FAILURE!!
If there is no failure, the charger launches a precharge phase (this step depends on the EV).
PRECHARGING...
1000 mA 320V
Once the precharge level is reached
and after receiving the charge permis-
sion, the charger displays
→
CHARGING…