User manual
DUM1017795-EN
27
GB mode
Once the GB mode selected, the charger performs an internal check and initialization.
Please wait for a few seconds.
Initialization...
→
The LED “CHARGER READY” ❹ flashes.
Connect vehicle
to start charge.
9
In the event of an error, the charger will display one of the two messages below:
Pwr module failure
0 OK and 2 Fail
or
No power module
Starting a charge in GB
Connect the charging cable to the vehicle (secure firmly).
→
The LED “CHARGER READY” ❹ flashes.
Vehicle connected
and press the GREEN button
Then the charger performs the insulation test.
INSULATION TEST...
INSUL. TEST COMPLETED
successfully
9
If there is an insulation failure:
Cancel charge...
INSULATION FAILURE!!