User manual
DUM1017795-EN
12
5. Specification
Technical specification
Mains supplies 3-phase L1/L2/L3 + GND 3x400V
AC
(50kW)
Mains 3-phase voltage range
V
AC
(P-P)
400 V
AC
± 10%
Earthed electrical system
TT or TN
Assigned frequency
f
50/60 Hz
± 10%
Maximum input current
I
AC
90 A
Max
Nominal input current
I
AC
80 A
Nom
Power Factor
PF
0,93
Nom
Efficiency
ɳ
95 %
Nom
Harmonic current @ nominal network voltage
THDi
32 %
Max
Internal AC input protection
Inrush current limitation per phase
I
INRUSH LIMIT
< 3 x I
AC
Max
MCB (Main Circuit Breaker)
I
BREAK
100 A
Nom
Breaking capacity of breaker
I
BREAK
6 kA
Max
Max earth leakage current
I
LEAKAGE
< 3,5 mA
Max
Overvoltage (IEC60664-1)
OVC III
Insulation protection Class
Class II
DC output
Output voltage
V
DC
500
(4)
Max
V
DC
200
Min
Output current
I
DC
125 A
(1)(2)
Max
I
DC
5 A
Min
Max Output Power
P
OUT
50kW
Max
Output connector
Swapped vehicle cable
Car Plug coupler
COMBO1 / COMBO2 / CHAdeMO / GB
Output cable length
6 m
Internal DC output protection
Hardware and software short circuit protection
Yes
Over voltage protection
V
DC
550
Nom
Overheating internal protection
-
70
°C
DC output contactor
Oui (2 pôles)
Rated Current Fuse (output)
I
FUSE
200
A
Galvanic isolation
V
input / output
4000
V
DC
Max time for DC line discharge < 60V
T
<60V
1
s
Embedded Insulation device
Response time (tan)
< 3sec. for asymmetrical fault
< 62sec. for symmetrical fault
Self test time
At power on and every 60s during charge.
Measurement method
Non-symmetrical fault detection done continuously
Symmetrical fault detection every minute
Isolation controller integrity check before each charge