6 - USE AND OPERATION
VIP80E
GB
6 - Pag. 7 / 13
6.4
LUMINOUS SIGNAL DESCRIPTION
Red light ; signals that the bar feeder is in stop
mode, or that it is in manual mode.
Green light; signals that the bar feeder is in
automatic mode.
Blue light; signals that the bar feeder is carrying
out the bar change.
6.5
BAR PREPARATION (sections and tubes)
The bars, before being loaded in stock, must be
chamfered in their lathe inlet end, in order to
remove any exceeding burrs.
In the case of tubes, insert a plug (A) in order to
create a bearing surface for the bar pusher and to
avoid that the coolant comes out.