5 - ADJUSTMENT AND SETUP
SMART320
EN
5 - Pag. 13 / 20
5.3.2 Bar guide plates - Adjustment
Preliminary procedure
• Remove the upper guard.
• Close the upper guide channel by pressing
on the keyboard (before the guard
opening) or the key on the solenoid valve for
guide channel opening/closing.
Bar guide plate adjustment
• Loosen the handle (A), lift the plate and tighten
the handle (A); repeat this operation on all the
plates.
• Prepare two bar remnants at least 1,200 mm
long.
• Load the two bars into the magazine, loosen
the handle (A) and let the plates drop against
the bars.