EN
4 - HANDLING AND INSTALLATION
SMART320
4 - Pag. 24 / 26
4.9.2 BAR FEEDER HANDLING WITHOUT POWER SUPPLY
Without power supply or in case of an emergency it is possible to move the pneumatic units
using the solenoid valves manually:
- By means of a small screwdriver press button (A) to position 1.
- With the same tool press button B, located on each solenoid valve, to move the unit.
FUNCTION DESCRIPTION
ABBREVIATION
A
Guide control solenoid valve
Guide channel closing
A1
Guide control solenoid valve
Guide channel opening
B
Clamp control solenoid valve
Clamp opening/closing
C
Bush control solenoid valve
Bush opening/closing
D
Flag control solenoid valve
Facing flag resetting
A18_MUM_04_03_01
A
B
C
A1
D