TANK-600 Em b e d d e d S ys te m
P a g e 87
NOTE:
The following discussion applies to DOS environment. Contact IEI support
or visit the IEI website for specific drivers for other operating systems.
The Watchdog Timer is provided to ensure that standalone systems can always recover
from catastrophic conditions that cause the CPU to crash. This condition may have
occurred by external EMIs or a software bug. When the CPU stops working correctly,
Watchdog Timer either performs a hardware reset (cold boot) or a Non-Maskable Interrupt
(NMI) to bring the system back to a known state.
A BIOS function call (INT 15H) is used to control the Watchdog Timer.
INT 15H:
AH – 6FH S u b -fu n c tio n :
AL – 2:
Sets the Watchdog Timer’s period.
BL:
Time-out value (Its unit-second is dependent on the item “Watchdog
Timer unit select” in CMOS setup).
Table C-1: AH-6FH Sub-function
Call sub-function 2 to set the time-out period of Watchdog Timer first. If the time-out value
is not zero, the Watchdog Timer starts counting down. When the timer value reaches zero,
the system resets. To ensure that this reset condition does not occur, calling sub-function
2 must periodically refresh the Watchdog Timer. However, the watchdog timer is disabled
if the time-out value is set to zero.
A tolerance of at least 10% must be maintained to avoid unknown routines within the
operating system (DOS), such as disk I/O that can be very time-consuming.
Содержание TANK-600 Series
Страница 13: ...TANK 600 Embedded Sys tem Page 1 Chapter 1 1 Introduction ...
Страница 20: ...TANK 600 Embedded Sys tem Page 8 Chapter 2 2 Unpacking ...
Страница 24: ...TANK 600 Embedded Sys tem Page 12 Chapter 3 3 Ins tallation ...
Страница 42: ...TANK 600 Embedded Sys tem Page 30 4 Sys tem Motherboard Chapter 4 ...
Страница 54: ...TANK 600 Embedded Sys tem Page 42 Chapter 5 5 BIOS ...
Страница 87: ...TANK 600 Embedded Sys tem Page 75 Appendix A A Regulatory Compliance ...
Страница 93: ...TANK 600 Embedded Sys tem Page 81 Appendix B B Safety Precautions ...
Страница 98: ...TANK 600 Embedded Sys tem Page 86 Appendix C C Watchdog Timer ...
Страница 101: ...TANK 600 Embedded Sys tem Page 89 Appendix D D Hazardous Materials Dis clos ure ...