prox.pad Installation/Programming Manual
4.5.7 Programming Facility Code
This option is used to set the facility code that is processed when you are using the facility code matching feature. The default value in
prox.pad is 1. IEI HID format proximity cards come with a facility code value of 11. When using the facility code matching feature,
the facility code of each card used on the prox.pad to gain access, must match the facility code programming with this command.
1. Enter Program Mode.
Press:
99 # Master Code *
The yellow LED flashes slowly.
2. Enter the facility code (value = 0 to 255).
Press:
32 # 2 # value # **
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.
4.5.8 Corporate 1000 Company ID
This option is only used when you are using corporate 1000 proximity cards and you are using the facility matching feature. When
using the facility code matching feature, the facility code of each card used on the prox.pad to gain access, must match the facility
code programming with this command. You must first select this type of card using command 30, option 20, which is discussed in
section 4.4.4, before this option will work. The command sequence is as follows:
1. Enter Program Mode.
Press:
99 # Master Code *
The yellow LED flashes slowly.
2. Enter the facility code (value = 0 to 4095; default = 4095).
Press:
35 # 0 # Facility Code # **
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.
Document # 6055676, Rev 2.2, D4b Page 75 of 86