prox.pad Installation/Programming Manual
4.3 Secured Series Front End LED Indicators/Sounder Operations
Table 11: prox.pad LED Indicators/Sounder Operations – Secured Series Mode
LED/Sounder
Visual/Audible Condition
Description
Yellow LED
Slow blink
Unit is in Program mode
Rapid blink
Verify mode is active (checking that the last two values in
sequence match)
Steady
Program error; entry error lockout (no keypress feedback)
Very rapid blink
Memory (eeprom) erase is in progress (command 46)
“Pulsing” rapid blink
Batch program of cards in progress (command 56); block
delete of users (command 58)
Bi-color LED
Steady red
Lock is locked
Steady green
Lock is energized (timed or latched)
Quick double red/green flash
Prox card read correctly
All LED's
Rapid red, yellow, green
sequencing
Power on/reset
Sounder
(system)
Very quick beep (10 ms) with
yellow LED blink every second
EEPROM read error during get system parameters; can
be turned off by running self-test
Sounder (after
PIN)
3 rapid beeps after
PIN not found
Sounder (after
card)
3 very rapid beeps
PIN not found, facility code/company ID mismatch and
access by facility mode enabled; incorrect card type
(option #20)
1 short beep
Valid card access
4.4 Secured Series Front End Mode Default Settings
Option
Default Setting
Option
Default Setting
Master Code
1234
Audio Keypress Feedback Enabled
Visual Keypress Feedback Enabled
Auto-Entry
Disabled
Anti-Passback
Enabled
Reader In/Out Select
In
Keypad In/Out Select
In
Prox Card Type
26-bit
Facility Match Required
Disabled
Facility Code
1
Corporate 1000 ID
4095
Document # 6055676, Rev 2.2, D4b Page 71 of 86