prox.pad Installation/Programming Manual
3.3.13 Programming the Green LED Active State
In Wiegand Front End Mode you can control how the green LED operates using the LED wire, which is the brown wire on connector
P3. When you program this option for an active high state, the green LED turns on when the wire is connected to positive voltage.
When you program this option for an active low state, the green LED turns on when the wire is connected to ground. The default is an
active high state.
1. Enter Program Mode.
Press:
99 # Master Code *
The yellow LED flashes slowly.
2. To set the green LED for an active high state, press:
30 # 12 # 1 # **
The yellow LED continues to blink slowly.
To set the green LED for an active low state, press:
30 # 12 # 0 # **
The yellow LED continues to blink slowly.
3. Exit Program Mode.
Press:
*
The yellow LED stops flashing.
3.3.14 Programming the Wiegand Pulse Width
If you panel requires a specific pulse width (the width of each individual data bit) you can program that with the parameter below. It's
programmable from 20
μS (micro-seconds) to 5100μS; the default value is 160μS. The value field in the command requires
a number from 1 to 255 in 20μS increments. For example is you want 200μS enter a value of 10 in the field. Only change
this option if your panel specifically states you need a specific pulse width.
1. Enter Program Mode.
Press:
99 # Master Code *
The yellow LED flashes slowly.
2. Enter the pulse width (value = 1 to 255; 20μS increments; default = 8, 160μS).
Press:
32 # 0 # value # **
3. Exit Program Mode.
Press: *
The yellow LED stops flashing.
Page 66 of 86 Document # 6055676, Rev 2.2, D4b