prox.pad Installation/Programming Manual
2.7.6 Reseting System Defaults and Erasing Memory
There are two methods for deleting programmed information from the prox.pad keypad. The first method is using command 40, which
resets the system defaults and the master code only. The second method is through command 46, which erases all the memory in the
prox.pad, except the transaction log.
Resetting the Master Code and System Defaults Only
Entering command 40 erases everything from the prox.pad memory except the user list and transaction log and restores the default
settings. This is useful if the prox.pad unit has experienced programming problems, or wish to delete earlier programming.
1. Enter Program Mode.
Press:
99 # Master Code *
The yellow LED flashes slowly.
2. Enter the command to reset system defaults.
Press:
40 # 00000 # 00000 # **
The yellow LED continues to blink slowly.
3. Exit Program Mode.
Press:
*
2.7.6.a Erasing Entire Memory/Resetting System Defaults
Entering command 46 deletes everything from the prox.pad memory including the user list but not the transaction log and restores the
default settings. This is used as a last resort if you need to erase a specific user and could not retrieve the Programmed User List.
1. Enter Program Mode.
Press:
99 # Master Code *
The yellow LED flashes slowly.
2. Enter the command to erase memory.
Press:
46 # 00000 # 00000 # **
The yellow LED blinks rapidly for several seconds until the memory is deleted.
3. Exit Program Mode.
Press:
*
Page 52 of 86 Document # 6055676, Rev 2.2, D4b