Advanced Setup
Select Dry Contact
Unoccupied operation:
Unoccupied Setpoints
Off
Select Dry Contact operation:
Occupied
Unocc-
upied
Setup
I5
Step #16 only appears if step #15 = Unoccupied.
After programming is complete, press the
MODE and FAN buttons at the same time
for two seconds to leave the Setup screens.
If no buttons are pressed, the display will
leave the setup screens after 30 seconds.
occupied
Setup
85
I6
55
unoccupied
Press
MODE
Page 22
Unoccupied
= the thermostat will enter the
Unoccupied mode when the Dry Contact is closed.
Occupied
= the thermo-
stat will enter the Occup-
ied mode when the Dry
Contact Contact is closed.
Off
= when the Dry Contact is
closed, the thermostat will turn
off.
Unoccupied
= when the
Dry Contact is closed,
the thermostat will con-
trol to the Unoccupied setpoints.