background image

 

 

 

 

 

 

 

 

 

 

 
 

BC2036-PTC 

 

 
 

Human Body Temperature 

 

Rapid Screening Device 

 

User Manual V1.0 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

BC2036-PTC

 

User Manual 

 

Содержание BC2036-PTC

Страница 1: ...BC2036 PTC Human Body Temperature Rapid Screening Device User Manual V1 0 BC2036 PTC User Manual ...

Страница 2: ...r power off or it will cause permanent damage to the thermal imager Caution The original packing box must be adopted during transportation Avoid violent shake or collide of thermal imager during utilization and transportation Caution For saving of thermal packing box and store in a electromagnetic field imager it is recommended to adopt the original cool dry and ventilated plout strong Caution Avo...

Страница 3: ...before delivery It is suggested to carry out temperature correction annually Caution Do not open the enclosure or modify without permission The maintenance can only be carried out by the personnel authorized by the company BC2036 PTC 3 User Manual ...

Страница 4: ...ving 12 3 3 4 Thermal Image Playback 12 3 3 5 Export of Saved Information 13 3 3 6 LCD Setting 13 3 3 7 Menu Operation Instruction 13 4 Operation Guidance 14 4 1 Operation Interface Description 14 4 1 1 Graphic Interface of Working Status Screen of Thermal Imager 14 4 1 2 Floating Bar Interface 16 4 1 3 Main Menu Interface 16 4 1 4 Sub menu Interface 17 4 2 Addition of Temperature Measurement Obje...

Страница 5: ...tem Setting 33 4 7File Management 36 4 7 1 Playback 36 4 7 2 Deletion 38 5 Technical Specifications 39 6 In Vivo Shell Temperature Conversion Table 41 7 Common Failure Countermeasures 41 5 BC2036 PTC User Manual ...

Страница 6: ...84 288 detector with a temperature scope of 20 C 50 C 1 2 Functions Functions include 11 optional color codes 11 optional languages 1 regional temperature measurement Customize shortcuts Power save mode LCD intensity control Video output NTSC or PAL system Time date setting Restore factory setting TF card unloading formatting TF card image capture video saving image capture voice or text notes Con...

Страница 7: ...S visible image and saving 2 LED fill lights Infrared and visible image fusion Fusion for High and Low Temperatures 1 3 Standard Configuration Thermal imager hand strap Carrying case Lithium battery Lens cap Optical disks for user manual statement analysis system TFcard 8G TF card reader Video output cable External 12V power adapter 2 ...

Страница 8: ...2 Brief Introduction of Thermal Imager 2 1 Function Buttons 7 1 4 3 2 5 6 ...

Страница 9: ...to cancel the current menu operation in menu mode Press the button to return to the active mode in frozen image or playback mode Press the button to switch among thermal image visible image and fusion in non menu and parameter modification mode Press the button to delete the measurement parameter when selecting a measurement parameter such as a measurement point 4 Frozen Saving Tag S To freeze or ...

Страница 10: ...perature measuring area is selected press OK button to pop out the attribute dialog box Press S button to switch the area position or size and select from four direction buttons to move the area position or change the size Up down left and right buttons can also be defined as shortcuts For details refer to the definition of trigger button 6 Trigger Shortcuts As a customize shortcut button trigger ...

Страница 11: ...2 2 Interface 1 2 3 4 6 ...

Страница 12: ...12V power requirement Positive central plug Attentions Do not plug the audio cable into the power interface this will cause damage to the metal pin of the power supply the external power can t be used 3 Basic Operation 3 1 Battery Installation and Replacement 3 1 1 Battery Loading Unloading Battery cartridge is in the handle of the device Push the push button at the bottom of the battery cover swi...

Страница 13: ...When inserting the battery please note that the end with contact spot should be inserted into the battery compartment first Close the battery cover and use the device after hearing a snap 8 ...

Страница 14: ... device may be damaged due to incorrect battery size or voltage 3 1 2 Battery Replacement When showing empty battery and blinking for about 1 minute and 50 seconds the device displays battery low prompt message and will automatically shut down after about 10 seconds Shutdown Prompt Replace the battery now 9 ...

Страница 15: ...ceed 50 of the battery capacity Battery should be charged at the environment temperature between0 40 charging at the ambient temperature of 0 will decrease the battery capacity charging at ambient temperature of over 40 may cause over temperature and damage Warning Do not disassemble extrude or stab the battery Do not short circuit the external contacts of the battery Keep the battery dry Do not p...

Страница 16: ...g point setting box The options below are available black body area setting shielding area setting reset amplitude comparison factor and black body temperature Press the direction button to select the black body area setting option press the middle OK button to set the black position and adopt the up down left and right direction buttons to move the red box to the black body with the red cursor ai...

Страница 17: ...pop out the floating panel menu select the Take Photo option in the menu and the system will save the image automatically Press S button and press this button again to save after the image is frozen Press S button continuously for 3 seconds to save the image automatically Press the Shortcut button to save the image by setting the shortcut as the Take Photo option 3 3 4 Thermal Image Playback There...

Страница 18: ...OK button to pop out the floating panel Select the icon by left and right buttons on the floating panel and press OK button to enter relevant interface Main menu interface select the menu icon by Up Down Left and Right buttons and press OK button to enter sub menu Sub menu interface select by up and down buttons If there is a tag right click to enter sub menu Parameter interface press up and down ...

Страница 19: ...y Default emissivity set 3 Reference Temperature Measurement Fixed temperature measurement for reference 4 Temperature Measurement Results Display the temperature value of the temperature measurement object If the reference temperature measurement is set the difference with the reference temperature measurement will be displayed 5 Point Temperature Measurement Icon Point temperature measurement cr...

Страница 20: ...ry levels 14 TF Capacity Display the TF card capacity used 15 Frozen Icon indicate that the image is frozen currently 16 Zoom Out Icon indicate that the image is enlarged currently 17 Video Recording Icon indicate that the current status is video recording status 18 Continuous image capture Icon indicate that the current status is continuous image capture status 19 Audio Recording Icon indicate th...

Страница 21: ... the temperature measurement target from left to right 4 1 3 Main Menu Interface Main Menu Interface Main menu item display the main menu items including 8 items i e file management temperature measurement setting image setting photo setting general setting network setting TF card management and system setting 16 ...

Страница 22: ...ntent each item corresponds to one item content which can be changed by left and right buttons indicates that there are sub menus 4 Parameter Options Press left and right buttons to select different parameters 4 2 Addition of Temperature Measurement Object This function is adopted for addition or deletion of temperature measurement objects Press OK button to pop out the floating menu select Add Te...

Страница 23: ...ed to save the video in MP4 format Press OK button to pop out the floating menu select Video Recording and press OK button as shown in the figure below Video Recording Interface Press stop button to end recording and return to the operation interface 4 4 Photo Taking This function is adopted to take photos and the saving format is JPG Press OK button to pop out the floating menu select Take Photo ...

Страница 24: ... the status bar when taking photos 4 5 Preview This function is adopted to preview the files saved Press OK button to pop out the floating menu select Preview and press OK button as shown in the figure below Preview Interface Press left and right buttons to switch files press OK button to open the files displayed right in the center and press C button to exit the preview mode 19 ...

Страница 25: ...e menu and press OK button to pop out the general setting dialog box User may set the seven items auto zeroing interval shortcut definition Bluetooth power saving mode LCD brightness adjustment temperature unit setting and distance unit setting Press up and down direction buttons to switch items Press left and right direction buttons to set the item contents indicates sub menu Press right button t...

Страница 26: ... etc When selecting Laser press shortcut button to open the laser sight and release the shortcut button to close the laser sight when selecting Lighting press the shortcut button to open or close the illuminator when selecting Edit Temperature Measurement Point 1 press the shortcut button to add or delete the temperature measurement point 1 when selecting Edit Temperature Measurement Area 1 press ...

Страница 27: ...uetooth device in the display box It takes effect immediately after activated and carry out scanning once automatically Bluetooth Menu Power saving mode power saving mode includes screen off and power off Screen OFF duration when there is no operation within defined duration the thermal imager will automatically shut down the display to save battery power Press any button except the power switch t...

Страница 28: ...automatically turn off the main power to save battery power The option set as 00 minute indicates that this function is not enabled Dialog Box of Power Saving Mode LCD brightness adjustment adjust the current LCD brightness and is effective all the time LCD Brightness Adjustment Interface 23 ...

Страница 29: ...own direction buttons to switch items Press left and right direction buttons to set the item contents indicates sub menu Press right button to enter Gear Set the temperature measurement gear of the thermal imager Balow lens Set different Balow lens and corresponding temperature measurement ranges Ambient temperature Once turned on the thermal imager will automatically detect the ambient temperatur...

Страница 30: ...rected temperature distance humidity and other items Press up and down direction buttons to switch items Press left and right direction buttons to set the item contents indicates sub menu Press right button to enter Emissivityfactor As different objects have different emissivities different emissivities can be set for different temperature measurement points When it is not set apply the system def...

Страница 31: ...is set to On A fixed temperature can be adopted as reference temperature 4 6 4 Image Setting Image Setting Menu Press OK button to pop out the floating panel press OK button to pop out the floating panel select Setting option to activate the main menu select Image Setting item in the setting menu and press OK button to pop out the image setting menu Users can set Auto Enhance mode infrared transpa...

Страница 32: ... to auto mode by pressing C button Auto mode and AutoEnhance mode can be switched by the AutoEnhance mode switch When selecting Auto the thermal imager will adjust the image hierarchy automatically When selecting AutoEnhance adjustment the high and low temperatures can be viewed in the temperature measurement screen of the thermal imager at the same time When selecting Manual user can adjust the i...

Страница 33: ...perature exceeds the alarm temperature set the color of the area exceeding the alarm temperature will be shown in the alarm color set The system provides 9 optional colors When the alarm color is set as Colorless it indicates that the original color of the screen will not be changed Alarm temperature set the alarm temperature It is valid only when the alarm type is set as On Alarm linkage include ...

Страница 34: ... that the original color of the screen will not be changed Upper limit of Isothermal zone set lower limit of isotherm Lower limit of isothermal zone set the lower limit of equal temperature Menu of Fusion for High and Low Temperatures Fusion for high and low temperatures three fusion types include OFF fusion for high temperature and fusion for low temperature When selecting fusion for high tempera...

Страница 35: ...le light When selecting fusion for low temperature and the actual temperature is lower than the fusion temperature set the infrared part of the fusion will be displayed as visible light 4 6 5 TF Card Management TF card uninstall dialog box TF card uninstalled successfully 30 ...

Страница 36: ...ard formatting Select the formatting option and press OK button to pop out the formatting prompt box Press OK to format immediately Press cancel or C button to cancel formatting Caution Please use this function with caution Before formatting please confirm that the file is no longer needed or has been backed up After formatting all the thermal images saved in the thermal imager will be lost and ca...

Страница 37: ...nnotation and text annotation Audio annotation is to add voice records when saving images text annotation is to add text information records when saving images The text information added must be imported into the device in a fixed format first Number of MultiShot set the number of continuous captures which can be set as 1 3 5 or 10 continuous shots MultiShot interval the time interval during conti...

Страница 38: ... floating panel select the Setting option to activate the main menu and select the System Setting option in the setting menu You can customize the system language time date format time date and factory reset items Press the up and down direction keys to switch between items Press the left and right direction keys to set the item content indicates that there is a lower menu Press the right key to e...

Страница 39: ...ress left and right direction buttons to switch items Press up and down direction buttons to set the item contents Note When the thermal imager lies idle for a long term as the internal battery level is limited it is necessary to readjust the system time after starting up Factory reset this function is adopted to restore factory settings Press OK button to pop out a prompt message dialog box Conti...

Страница 40: ...e number software version number and MAC address of the thermal imager Import create a new DCIM Import directory on the TF card and set the import file name as PicNote cfg File content format Note Note1 Note2 Note3 Not over 20 characters per line At the completion of import restart the device to take effect Export first confirm that TF card is in the device and click the export button in the menu ...

Страница 41: ...g option to activate the main menu select File Management menu in Setting menu and press the OK button to open the image saved in the thermal imager The image arrangement format is displayed a nine screen mode Press up down left and right direction buttons to switch the saved image Press C button to quit the image opened and return to the temperature measurement status 36 ...

Страница 42: ...t the image opened and return to the temperature measurement status Video File Playback Interface In the video playback interface select the button on the play status bar by left and right buttons press OK button to take effect and press up and down buttons to display and hide the play status bar press up button to display and down button to hide The icon buttons from left to right are play pause ...

Страница 43: ...ght are previous section next section audio recording audio playback text playback 4 7 2 Deletion This function is adopted to delete files saved in TF card After opening the file management select the file to be deleted by pressing up down left and right buttons and press S button to pop out the file deletion prompt box When pressing OK button delete the image file selected currently If the image ...

Страница 44: ...n LED fill set with two built in LED fill Performance camera lights lights Frame frequency 50HZ 60HZ optional Video Output PAL NTSC optional LCD 3 5 TFT LCD 640 480 color with touch screen Figure Pallet 11 optional pallets Infrared image and visible image can be switched quickly and Display Figure display fusion of infrared image and visible image is available Image Adjustment Auto manual adjustme...

Страница 45: ... machine can be uploaded File Directory Optional at local machine can be uploaded Battery Rechargeable replaceable lithium batteries Working Time of Continuous operation for over 4 hours 50 LCD brightness Power Battery LED light is off Charging or random charging by smart charger AC power System Charging Mode adapter or 12V on board power supply Charging Time Random charging for 1 5 hours to reach...

Страница 46: ...y problem during utilization of the thermal imager please adopt the table below for maintenance If the problem cannot be resolved please disconnect the power supply and contact our maintenance department Symptoms Causes Solutions The battery isn t installed or incorrectly installed Install or reinstall the battery Failure to startup the Thermal The battery power is exhausted Imager Replace the bat...

Страница 47: ...echarge the rechargeable battery The rechargeable battery power is exhausted and the battery can no longer be charged Replace it with a new rechargeable battery The lens cap is not removed Remove the lens cap No thermal image In frozen image status Press quit button to return to the real time temperature measurement status The thermal image is turned into Black and white color code is selected bla...

Отзывы: