background image

Installation Guide:

for the Warmup 

Tempo

 Digital Programmable Thermostat

 Introduction

The 

Tempo

 thermostat is designed to aid in the comfort of your home by providing timed regulation of your Warmup underfloor heating 

system. The thermostat is designed to receive temperature input signals from the following sensors:

1.  Air sensor located inside the thermostat

2. 

Floor sensor installed in the floor to be heated supplied with thermostat

The thermostat is not a safety device and should only be used with Warmup heating products. In order to avoid damaging your flooring 

the correct floor type must be selected during the thermostat programming process.

Technical Specification

:

• 

Supply voltage: 120-240V, AC +10/ -15%, 50/60Hz               

• 

Maximum Switch Load:  15A resistive Note: This product is not designed to be used with any inductive load.

• 

Sensors: Air & Floor

• 

Battery Backup: 3 Months (CR2032 Battery Provided)

• 

Floor sensor Type:  NTC (10K) - Maximum Temperature 104°F (40°C)

WARNING – Important safety note

This product uses mains voltage electricity and work should only be carried out by a qualified electrician. You should always isolate the 

power supply before attempting to install or repair the 

Tempo

 thermostat. The thermostat should not be put into operation unless you 

are certain that the entire heating installation complies with current general safety requirements for electrical installations. Electrical 

installation must be in accordance with latest local electrical wiring code.

The world’s 

best-selling

 floor heating brand™

Important Notices

FCC Notice

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause 

harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired opera-

tion.

Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s au

-

thority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment 

generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause 

harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off 

and on, the user is encouraged to try to correct the interference by one or more of the following measures:

– Reorient or relocate the receiving antenna.

– Increase the separation between the equipment and receiver.

– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

– Consult the dealer or an experienced radio TV technician for help.

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

WET AREAS

Install the thermostat a minimum of 5ft away from showers, tubs and other sources of splashing water.

IC Statement

This device complies with Industry Canada Licence-exempt RSS-247. Operation is subject to the following two conditions:

(1) This device may not cause interference, and

(2) This device must accept any interference, including interference that may cause undesired operation of the device.

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons

Содержание Tempo

Страница 1: ...erence received including interference that may cause undesired opera tion Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the u...

Страница 2: ...f thermostat 2 Unscrew both closing screws at the bottom until they don t turn any further 3 Release front housing by gripping lower half of outer frame and pulling outwards then upwards Place front h...

Страница 3: ...ill show whether the thermostat is at Comfort or Setback temperature The icon will be displayed when Comfort 1 2 is the target temperature Only used with the Fil Pilote 3 This icon is displayed when t...

Страница 4: ...wer Battery is low Getting started In order to program the Tempo thermostat all you need to do is slide the Program Slide control from the top position to the bottom position customising the program a...

Страница 5: ...he next day If you hold the Main Button for 3 seconds it will copy the start time to the next day Tip If you want to set the thermostat so that it is keeping the comfort temperature all day and only s...

Страница 6: ...t the installer setting mode Installer Step Setting Configured Default Value LCD Example 1 Change clock format 12hr 24hr 12 2 Change unit of measurement Degree C F F 3 Change sensor used to target tem...

Страница 7: ...r is lost Heating starts too early If your heating is coming on too early then this may be because the Adaptive Learning function is turned on This function allows your thermostat to learn how long it...

Страница 8: ...sole responsibility shall be to repair or replace the product within the terms stated above WARMUP SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMA...