Setup Menu F1
Set the communication speed in terms of PC program.
The matching values of communication speed have to be required between device and PC p
rogram.
Baud rates of 4800bps, 9600bps (Default), 19200bps, 38400bps, 57600bps and 115200bp
s are supported, and 9600bps is recommended.
When you change DIP switch, the value of ‘Baud Rate’ will be displayed on LCD.
If a TCP/IP module is being used, the baud rate setting must be set the same as the TCP/IP m
odule setting.
If a TCP/IP module is being used, the Baud Rate setting must be the same as the T
CP/IP module setting.
Troubleshooting Communication Problems
Step 1. Match the communication address between the device and the Application
Software.
Step 2. Match the Baud Rate between the device and the Application Software.
Step 3. Ensure that the COM port setting in the Application Software is correct.
Step 4. Ensure that the communication settings in the Application Software are as
follows;
1) Parity Bit: None 2) Data Bit: 8 Bits 3) Stop Bit: 1 Bit
1.4
Reader1 Mode
You can decide which combination of RF card, fingerprint and password verification you wis
h to use on Reader1 (the iCON100 device itself).
To change the Access Mode for Reader 1, press <ENT>, select the “DESIRED MODE” by press
ing <4> or <6>, and then press <ENT> again to confirm.