INSTALLATION TIPS & CHECK POINT
p.16
1.2
Recommended Cable Type and Permissible Length of Cable
Reference
Description
Cable Specification
Maximum Distance
①
Power (DC12V)
DC Power -> iCON100
Belden #9409, 18 AW
G
2 conductor, unshielde
d
3m
②*
Reader (Power and Dat
a)
Extra Reader -> iCON1
00
Belden #9512, 22 AW
G
4 conductor, shielded
150m
Belden #9514, 22 AW
G
8 conductor, shielded
③
Door Contact
Exit Button
Sensor Input
Input -> iCON100
Belden #9512, 22 AW
G
4 conductor, shielded
300m
Belden #9514, 22 AW
G
8 conductor, shielded
④
Door Lock, Alarm Devic
e
Lock (Alarm) -> iCON1
00
Belden #9409, 18AWG
2 conductor, unshielde
d
300m
⑤
RS232 Cable
Converter -> Host P.C.
Belden #9829, 24 AW
G
2-twisted pair, shielded
15m
⑥
RS485 Cable
iCON100 -> iCON100
iCON100 -> Converter
Belden #9829, 24 AW
G
2-twisted pair, shielded
1,200m
RS422 Cable
iCON100 -> iCON100
iCON100 -> Converter
Belden #9830, 24 AW
G
3-twisted pair, shielded