background image

Quick Installation Guide 

 

 
 
 
 

 
 
 
 

 
 
 
 

 
 
 

 
 
 
 

 
 
 
 

 
 
 
 

 
 
 
 

 
 
 
 

 
 
 
 

 
 
 
 

 

 

Access Controller 

 

Содержание Star iCON100

Страница 1: ...Quick Installation Guide Access Controller ...

Страница 2: ...oduct with tools such as driver in hand when power is being supplied Do not drop liquid like water onto the product and give the product a severe shock Do not place magnetic objects near the product Do not replace the wiring cables installed by experts Do not let anyone but the manger touch the product except using it for normal purpose Do not use the product under direct sunlight or near heat pro...

Страница 3: ...ain Unit User s Manual Diode Register 1ea 1copy 2ea 5ea 3 Board Layout Figure iCON100 Control Board Layout 1 Fixing Hole These holes are to attach the iCON100 board to the Nema case 2 2Pin DIP Switches These switches are to set the type of reader input 26bit wiegand for iCON100 34bit wiegand for iCON100 SR 3 8PIN DIP Switches Fixing Hole 2 Pin DIP Switch 8 Pin DIP Switch Initialization Switch ...

Страница 4: ...he Input 3 port LED is turned on when Input signal is perceived 11 Input 2 Port This is the Input 2 port LED is turned on when Input signal is perceived 12 Input 1 Port This is the Input 1 port LED is turned on when Input signal is perceived 13 MCU Module connecter It s the terminal for MCU module connection 14 IIM7100A Connector It s the terminal for IIM7100A Optional connection 15 Reader 2 Port ...

Страница 5: ... RS 422 Serial Communication Port This is the RS422 communication port to directly connect this board to PC in long distance Maximum of 32 boards can be communicated with each other by Multi Drop You need RS422 RS232 converter to connect RS422 port to PC 27 Power Status LED This is the LED to show the status of power supply 28 RX Status LED This is the LED to show status of reception during commun...

Страница 6: ...N GUIDE 6 4 INSTALLATION TIPS CHECK POINT 4 1 Check Points before Installation 4 1 1 Selection of Cable System installation cabling will be configured as follow Figure System Installation Layout Door Lock Door Lock Exit Button Exit Button ...

Страница 7: ...ed Door Contact Exit Button Sensor Input Input iCON100 Belden 9512 22 AWG 4 conductor shielded 300m Belden 9514 22 AWG 8 conductor shielded Door Lock Alarm Device Lock Alarm iCON100 Belden 9409 18AWG 2 conductor unshielded 300m RS232 Cable Converter Host P C Belden 9829 24 AWG 2 twisted pair shielded 15m RS485 Cable iCON100 iCON100 iCON100 Converter Belden 9829 24 AWG 2 twisted pair shielded 1 200...

Страница 8: ...fore the center of the bit therefore the termination resistors are not required However if you install the cable to maximum length the impedance of cable and network is mismatched and the transmitted signal is overlapped by the reflected signal In this case it is recommended to add termination resistors to the end of the receiver lines A 120Ω resistor can be used for termination resistor in parall...

Страница 9: ...sis ground then connect one end of shield wire to power ground GND of iCON100 Note that if the chassis ground is not properly connected to the earth and floated from the ground level then grounding to the chassis ground will give the worst communication in this case we recommend to using power ground instead of chassis ground Figure Grounding System 4 2 4 Reverse Diode Connection If you connect an...

Страница 10: ...en initialization is done and system restarts automatically Figure Switches Location Figure Magnification of Switches Figure LCD Display Caution If you initialize the iCON100 all data such as user ID baud rate door setting time schedule and event information stored in the controller will be cleared and the default values factory setting values will be reloaded Therefore the Initialization should b...

Страница 11: ...gand type format Using 26bit Wiegand format reader RF10 20 30 70 RFK101 34bit Wiegand type format Using 34bit Wiegand format reader SR10 20 30 SRK101 If DIP switch turns from ON to OFF or OFF to ON buzzer is generated If the buzzer doesn t stop after the DIP switch is changed it means ID information or event is stored in the memory In this case delete existing ID and event by initialization then y...

Страница 12: ... sum value of each switch set to ON position Board ID can be set from 0 to 31 The default value of board ID is 0 5 channel DIP switch is set to OFF position Refer to the example below Caution Each Board ID on the same communication loop must be not duplicated If the same Board IDs are on the same loop the communication error will occur Figure Position of Board ID Setting Switch Communication ID 0 ...

Страница 13: ...cation software STARWATCH DUAL PRO I II and STARWATCH STANDARD and the baud rate of all products on the same loop must be same If you use ver 6 0 and lower with ver A1 0 and higher together set the baud rate to 9600bps only When you only use ver A 1 0 and higher you can set other baud rate including 9600bps If you set high baud rate in bad environment for communication communication may not proper...

Страница 14: ... 2 2K resistance between Input wire ex Orange and GND Firstly you choose to use Cut Off Check Follow the process as F2 SETUP MENU 5 IN OUT DEFINE 21 CUT OFF CHECK For setting of output follow the process as F2 SETUP MENU 5 IN OUT DEFINE 18 CUT OFF ALARM Figure 2 2K Resistance Connection for Cut Off Check 5 4 3 Output Connections Door Lock Power Fail Safe Connection Relay 1 Connect COM port of Rela...

Страница 15: ...ions Proximity Reader Connection Connect wire of the Proximity Reader to DC 12V of Reader port Connect wire of the Proximity Reader to GND of Reader port Connect Data 0 wire of the Proximity Reader to D0 of Reader Port Connect Data 1 wire of the Proximity Reader to D1 of Reader Port Compatible Readers iCON100 Standard 26bit Wiegand Format Proximity Readers Standard 26bit Wiegand 8bit Burst Format ...

Страница 16: ...ication Port Connection A 9 pin connector Serial communication connector female is required to connect the iCON100 to a host computer via RS232 communication Please follow the instructions Connect RS232 TX port of iCON100 to the pin 2 RX of the 9 pin connector Connect RS232 RX port of iCON100 to the pin 3 TX of the 9 pin connector Connect RS232 GND of iCON100 to the pin 5 of the 9 pin connector Pl...

Страница 17: ... the converter and the device is too far Please follow the instructions below Connect RS422 TX Gray wire of iCON100 to RS422 RX port of converter Connect RS422 TX Yellow wire of iCON100 to RS422 RX port of converter Connect RS422 RX Brown wire of iCON100 to RS422 TX port of converter Connect RS422 RX Blue wire of iCON100 to RS422 TX port of converter Plug in the RS232 9PIN connector of the convert...

Страница 18: ...ct RS422 RX of one iCON100 to RS422 RX of another iCON100 Connect RS422 RX of one iCON100 to RS422 RX of another iCON100 Second you have to connect one of RS422 port of iCON100 to RS422 RS232 converter Connect RS422 TX of the one iCON100 to RX port of the converter Connect RS422 TX of the one iCON100 to RX port of the converter Connect RS422 RX of the one iCON100 to TX port of the converter Connec...

Страница 19: ... Module to iCON100 1 As below figure Insert TCP IP module IIM7100A to iCON100 in right direction Direction of arrows have to be matched between iCON100 and TCP IP module IIM7100A iCON100 Figure TCP IP module IIM7100A Connection 2 As below figure connect LAN cable to TCP IP RJ 45 jack Figure LAN Connection Connection Complete ...

Страница 20: ...100A Configuration Tool The Program to set network and check operation status is contained in Application software iTDC PRO I II STARWATCH STANDARD CD Install IIM100A Configuration Tool and then set TCP IP Module information for communication environment 2 Network Information Setting After TCP IP Module IIM7100 setting program IIM100A Configuration Tool is installed run Start Program Wiznet 7100A_...

Страница 21: ...for Port 0 0 0 0 for Server IP default 0 for Server IP Port Select Server Mode for Network Mode Refer to table below Column Name Setting Value Local IP The IP address assigned from corresponding network Not duplicated Gateway The Gateway assigned from corresponding network Not duplicated Subnet Mask The Subnet Mask assigned from corresponding network Not duplicated Port above 5000 Server IP 0 0 0 ...

Страница 22: ...ize and Char of selected TCP IP module Select 30000 for Inactivity Time 0 for Time 0 for Size 00 for Char Refer to table below Column Name Setting Value Inactivity Time 30000 Time 0 Size 0 Char 00 8 If all setting process is completed click Setting to apply network information to TCP IP module After setting is completed Complete Setting message is displayed Click OK and finish setting process ...

Страница 23: ...and iCON100 7 INITIALIZATION 7 1 Initialization of iCON100 Initialization is needed before initial installation or when any function is not operated properly For initialization press 2 initialization switches simultaneously then keep pressing more than 2 seconds Once buzzer sound is generated release 2 switches then initialization is done and system restart automatically After all initialization p...

Страница 24: ...rmation and event data stored in the Controller will be cleared Therefore the Initialization should be performed by authorized person only It is strongly recommended to upload all ID information and events data before initialization After the initialization you should transmit ID Time and Door definition from software to the device PRESS SYSTEM INIT WAITING Caution ...

Отзывы: