101-001 (iTDC), 101-002 (EIO88), 101-145 (iTDCSR) -9- Users Manual
IDTeck – iTDC 2~4 DOOR ACCESS CONTROLLER
When door is opened by force, the door contact sensor is activated then
forced door open alarm
will be
generated until the door is closed. For this application, you have to install door contact sensor (Reed
Switch) to the door and you have to properly set door contact time and outputs to alarm devices.
Duress Alarm / Alarm Arm – Disarm Code
In case of duress, (or
External Alarm Arm - Disarm
) enter the 2 digits Duress Password and <ENT> key
before the normal access process. The door will be opened as normal but the duress alarm is also
generated at the same time and the duress alarm output will be activated to TTL output and alarm event
will be sent to the host PC.
3.2 BOARD LAYOUT
Figure: iTDC Control Board Layout