101-001 (iTDC), 101-002 (EIO88), 101-145 (iTDCSR) -35- Users Manual
IDTeck – iTDC 2~4 DOOR ACCESS CONTROLLER
Select
[ID COUNT]
in the
[SETUP MENU F3]
then set-up the maximum User ID to be registered into
iTDC. Follow the steps to set-up ID COUNT.
The
Master ID
for
iTDC-SR
is
10 digits
number (
Default setting “0000000000”
).
☞
You will see this error message when you press
<ENT>
key in the
[ID COUNT]
menu and it tells you that some events are still
existing in the EVENT Buffer and you may lost the data when you
change the ID COUNT. You may try this setting again after
uploading the events to the host PC
or deleting them, using the
[SETUP MENU F2]
->
[EVENT CLEAR]
.
☞
You will see this error message when you try to change ID COUNT
less than the total registered User ID. In this case you have to delete
some User ID or clear the User ID, using the
[SETUP MENU F2]
-
>
[ID CLEAR]
first then try again from the beginning.
EVENT MEMORY
ID TOTAL
ID COUNT
<ESC>
STAR iTDC [F1]
Enter the number from 1000 to 20000
ID COUNT
ENTER ID
<ENT>
<ENT>
Initial Display
STAR iTDC [F1]
Press <F3> + <4> or <6>
Select [
ID COUNT]
8 times <0> + <ENT>
“MASTER ID” + <ENT>