101-001 (iTDC), 101-002 (EIO88), 101-145 (iTDCSR) -41- Users Manual
IDTeck – iTDC 2~4 DOOR ACCESS CONTROLLER
10.1.1 READER MODE SETTING
* READER2, READER3 and READER4 MODE set-up is the same as above.
10.1.2 ANTI-PASS-BACK MODE SETTING
* DOOR2 APB mode set-up is the same as above.
READER1
READER1
☞
. It shows READER1 MODE is set to RF ONLY operating mode.
If you want to change the mode to RF+PASSWORD operating
mode, then press <ENT> key.
READER1
☞
. Now you can change the mode by pressing <4> or <6> key to
toggle the mode. If you want to set-up the mode displayed then
press <ENT> key to accept this mode.
Note:
RF ONLY: The door is accessible with the proximity card alone.
RF+PASSWORD: The door is accessible with the proximity card
and Password.
DOOR 1 APB
DOOR 1 APB
DOOR 1 APB
☞
. It shows Door1 anti-pass-back operation is not used. Press
<ENT> key. (
It only applies when the Door has Exit Reader
)
z
For Door1 (2), you must have Reader #1(#2) for entry and
Reader #3(#4) for exit
☞
. Press <4> or <6> key for searching the APB mode.
Press <ENT> key to select the mode.
NOT USE: Anti-pass-back mode is not applied.
USE (ALONE): Door1 (2) Anti-pass-back mode is separately applied.
USE (ZONE): Door1 (2) Anti-pass-back mode is applied together.
Note: If you select USE (ZONE) then the APB flag will be affected
to Door1 and Door2. DOOR2 APB mode is set automatically.
Example: When you select USE (ALONE) then Door2 entry is possible
after you got in through Door1.
When you select USE (ZONE) then Door2 entry is not
possible after you got in through Door1. (APB error)
DOOR 1 APB
☞
. If you select All Clear then iTDC will clear all APB flags and all
users are not allowed Exit first
READER 1 MODE
RF+PASSWORD
RF Only (default)
<ENT>
Seaching key<4> or <6>