Specifications
Connector type
SUB D 25 point female
Cabling
Pin1=Preset1 Pin2=Preset2 Pin3=Preset3... up to16
Pin 19=alarme1 Pin 20=alarme2 … up to 24
Pin25=Masse
Max Length.
10 metres
Port « Data »
Le DEP has a supplementary RS 232 port called « Data », aimed at receiving data
from the UECP protocol (SPB490 standard) where a flow of dynamic RDS can be
received (WARNING this flow is not legal in all countries!)
Connector type
Male
Cabling
2=RX 3=TX 5=Ground
Max Length.
10 metres